Configuration utility error messages – Dell PowerEdge RAID Controller H200 User Manual

Page 64

Advertising
background image

64

Troubleshooting

Configuration Utility Error Messages

NOTE:

These error messages are displayed inside the Configuration Utility.

Restart your system and retry if you encounter any of these.

NOTE:

If the error message continues to be displayed even after following the

steps mentioned in Table 7-3 for the resolution of the error, contact Dell Support for
advanced troubleshooting. For information on how to contact Dell Technical
Support, see "Getting Help" on page 73.

Table 7-3.

Configuration Utility Error Messages

Message

Meaning

Suggested Solution

An error occurred

while reading

non-volatile

settings.

An error occurred while
reading any one of a
number of settings from
the firmware.

Reseat the controller
and reboot.

An error occurred

while reading current

controller settings.

Controller setup and
initialization has failed.

Reboot the system.

Advanced Device

Properties settings

not found.

Failed to read vital
configuration page from
firmware.

Reflash the firmware
and reboot.

Error obtaining

PHY properties

configuration

information.

Failed to read vital
configuration page from
firmware.

Reflash the firmware
and reboot.

Configuration Utility

Options Image

checksum error.

Failed to properly read
Configuration Utility
options from flash.

Restart and retry. If the
issue persists, reflash
the firmware on the
controller.

Can't load default

Configuration

Utility options.

Failed to allocate memory
for Configuration Utility
options structure.

An error occurred

while writing

non-volatile

settings.

An error occurred while
writing one or more settings
to the firmware.

PERC H200.book Page 64 Tuesday, July 13, 2010 4:15 PM