Dell PowerEdge VRTX User Manual

Page 104

Advertising
background image

Error Code

Message Information

PST0132

Message

CMOS failed.

LCD Message

CMOS failed. Power cycle system.

Details

System BIOS detected a failure with CMOS memory during system
POST.

Action

Check system event log for CMOS battery exceptions. Remove and
reapply input power. If the issue persists, see

Getting Help

.

PST0133

Message

DMA controller failed.

LCD Message

DMA controller failed. Power cycle system.

Details

System BIOS detected a failure with the DMA controller during
system POST.

Action

Remove and reapply input power.

PST0134

Message

Interrupt controller failed.

LCD Message

Interrupt controller failed. Power cycle system.

Details

System BIOS detected a failure with the interrupt controller during
system POST.

Action

Remove and reapply input power. If the issue persists, see

Getting

Help

.

PST0135

Message

Timer refresh failed.

LCD Message

Timer refresh failed. Power cycle system..

Details

System BIOS detected a timer refresh failure during system POST.

Action

Remove and reapply input power. If the issue persists, see

Getting

Help

.

PST0136

Message

Programmable interval timer error.

LCD Message

Programmable interval timer error. Power cycle system.

Details

System BIOS detected an failure with the programmable interval
timer during POST.

Action

Remove and reapply input power. If the issue persists, see

Getting

Help

.

PST0137

Message

Parity error.

LCD Message

Parity error. Power cycle system.

104