Dell PowerEdge VRTX User Manual

Page 107

Advertising
background image

Error Code

Message Information

LCD Message

Incorrect memory configuration. Review User Guide.

Details

System BIOS detected an invalid memory population.

Action

Reinstall memory to match supported memory configuration.

PST0254

Message

General failure after video.

LCD Message

General failure after video. Check screen message.

Details

System BIOS detected a functional or configuration issue during
system POST.

Action

Check system video and review event log for additional information.

PST0256

Message

POST fatal error detected.

LCD Message

POST fatal error detected.

Details

System BIOS detected a functional or configuration issue during
system POST.

Action

Check system video and review event log for additional information.

PSU0001

Message

Power supply <

number

> failed.

LCD Message

PSU <

number

> failed. Check PSU.

Action

Remove and reinstall the power supply. If the issue persists, see

Getting Help

.

PSU0002

Message

A predictive failure detected on power supply <

number

>.

LCD Message

Predictive failure on PSU <

number

>. Check PSU.

Details

System performance and power redundancy may be degraded or
lost.

Action

Remove and reinstall the power supply at the next service window. If
the issue persists, see

Getting Help

.

PSU0003

Message

The power input for power supply <

number

> is lost.

LCD Message

Power input for PSU <

number

> is lost. Check PSU cables.

Details

The power supply is installed correctly but an input source is not
connected or is not functional.

Action

Verify the input source is attached to the power supply. Verify the
input power is within the operating requirements for the power
supply.

107