Dell PowerEdge VRTX User Manual

Page 93

Advertising
background image

Error Code

Message Information

MEM0010

Message

Memory device at location <

location

> is over heating.

LCD Message

Memory device <

location

> is over heating. Check fans.

Details

System performance is degraded.

Action

If unexpected, review system logs for power or thermal exceptions.

MEM0022

Message

Memory device at location <

location

> is absent.

Details

The memory may not be seated correctly, misconfigured, or has
failed. Memory size is reduced.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

MEM0701

Message

Correctable memory error rate exceeded for <

location

>.

Details

The memory may not be operational. This an early indicator of a
possible future uncorrectable error.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

MEM0702

Message

Correctable memory error rate exceeded for <

location

>.

LCD Message

Correctable memory error rate exceeded for <

location

>. Re-seat

memory.

Details

The memory may not be operational. This an early indicator of a
possible future uncorrectable error.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

MEM1001

Message

Memory device at location <

location

> failed to transition to a running

state.

LCD Message

Memory device <

location

> failed to transition to a running state. Re-

seat memory

Details

The memory may not be operational. This an early indicator of a
possible future uncorrectable error.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

MEM1003

Message

Memory device at location <

location

> failed to transition to in test.

Details

The memory may not be operational. This an early indicator of a
possible future uncorrectable error.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

93

Advertising