Error Code

Message Information

Details

System hardware detected an over voltage or under voltage
condition.

If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.
2. Remove the processor module. Inspect processor socket for

bent pins.

3. If the issue persists, see

Getting Help

.

VLT0102

Message

Processor module <

name

> voltage is greater than the upper warning

threshold.

LCD Message

Processor module <

name

> voltage is outside of range.

Details

System hardware detected an over voltage or under voltage
condition.

If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.
2. Remove the processor module. Inspect processor socket for

bent pins.

3. If the issue persists, see

Getting Help

.

VLT0103

Message

Processor module <

name

> voltage is greater than the upper critical

threshold.

LCD Message

Processor module <

name

> voltage is outside of range.

Details

System hardware detected an over voltage or under voltage
condition.

If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.

Action

1. Review system logs for power supply exceptions.
2. Remove the processor module. Inspect processor socket for

bent pins.

3. If the issue persists, see

Getting Help

.

VLT0104

Message

Processor module <

name

> voltage is outside of the allowable range.

LCD Message

Processor module <

name

> voltage is outside of range.

127