Error Code

Message Information

PCI1344

Message

An I/O channel check error was detected.

LCD Message

An I/O channel check error was detected. Power cycle system.

Action

Cycle input power, update component drivers, if device is removable,
reinstall the device.

PCI1346

Message

A software error was detected on a component at slot <

number

>.

Action

Reboot the system and update the component drivers.

PCI1348

Message

A PCI parity error was detected on a component at slot <

number

>.

LCD Message

PCI parity error on slot <

number

>. Re-seat PCI card.

Details

System performance may be degraded, or system may fail to operate.

Action

Cycle input power, update component drivers, if device is removable,
reinstall the device.

PCI1350

Message

A PCI system error was detected on a component at slot <

number

>.

LCD Message

PCI parity error on slot <

number

>. Re-seat PCI card.

Details

System performance may be degraded, or system may fail to operate.

Action

Cycle input power, update component drivers, if device is removable,
reinstall the device.

PCI1354

Message

A bus correctable error was detected on a component at slot
<

number

>.

Details

System performance may be degraded.

Action

Cycle input power, update component drivers, remove and reinstall
the device at the next scheduled service time.

PCI1356

Message

A bus uncorrectable error was detected on a component at slot
<

number

>.

Details

System performance may be degraded, or system may fail to operate.

Action

Cycle input power, update component drivers, if device is removable,
reinstall the device.

PCI1358

Message

A fatal error was detected on a component at slot <

number

>.

LCD Message

Fatal error on slot <

number

>. Re-seat PCI card.

Details

System performance may be degraded, or system may fail to operate.