CMC indicators

Figure 22. CMC indicators

1.

status/identification indicator (CMC 1)

2.

power indicator (CMC 1)

3.

power indicator (CMC 2)

4.

status/identification indicator (CMC 2)

The CMC indicators on the back panel of the enclosure provide the following information:

Indicator

Description

Power indicator

Green

The CMC is receiving power.

Off

The CMC is not receiving power.

Status indicator

Blue

The CMC is active and operating normally.

Amber

The CMC is in fault condition.

CMC features

The CMC provides the following multiple systems management functions:

Enclosure-level real-time automatic power and thermal management:

– Monitors system power requirements and supports the optional Dynamic Power Supply Engagement (DPSE)

mode. The DPSE mode improves power efficiency by allowing the CMC to dynamically place power supplies in

standby mode, depending on the load and redundancy requirements.

– Reports real-time power consumption, which includes logging high and low points with a time stamp.
– Supports setting an optional enclosure Maximum Power Limit, which either alerts or takes actions, such as

throttling server modules and/or preventing the power up of new server modules to keep the enclosure under

the defined maximum power limit.

– Monitors and automatically controls cooling fans based on actual ambient and internal temperature

measurements.