The following table provides guidelines for installing expansion cards to ensure proper cooling and mechanical fit. The
expansion cards with the highest priority must be installed first using the slot priority indicated. All other expansion
cards must be installed in card priority and slot priority order.

Table 2. Expansion card installation order

Card Priority

Card Type

Form Factor

Slot Priority

Maximum Allowed

1

Integrated RAID

N/A

INT_STORAGE_1,
INT_STORAGE_2

2

2

External SAS RAID

Standard height

3, 2

2

Low profile

6, 5

2

3

GPU

Standard height

2, 3, 1

3

4

10 Gb NICs

Standard height

2, 3, 1

3

Low profile

6, 5, 7, 4, 8

5

5

FC HBA

Standard height

2, 3, 1

3

Low profile

6, 5, 7, 4, 8

5

6

1Gb NICs

Standard height

2, 3, 1

3

Low profile

6, 5, 7, 4, 8

5

7

SAS Non-RAID

Standard height

2, 3, 1

2

Low profile

6, 5, 7, 4, 8

2

Expansion card operational power status

The following table provides information on the operational power status of the expansion cards when:

the expansion card is installed in a PCIe slot mapped to a server module

the system cover is installed

Chassis Status

Server Module Status

Expansion Card Status

Off

Off

Off

Standby

Off

Off

On

Off

On for 5 minutes and then Off.

NOTE: The expansion card
status turns to Off immediately if
the system cover is removed.

On

On

On

The following table provides information on the operational power status of an expansion card when:

the expansion card is replaced in the PCIe slot

the system cover is removed