Installing a cooling fan, Cooling-fan assembly, Removing the cooling-fan assembly – Dell PowerEdge VRTX User Manual

Page 68

Advertising
background image

Figure 48. Removing and installing a cooling fan

1.

cooling-fan assembly

2.

fan release tab

3.

cooling fans (6)

4.

cooling-fan connectors (6)

Installing a cooling fan

CAUTION: Many repairs may only be done by a certified service technician. You should only perform

troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or

telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your

warranty. Read and follow the safety instructions that came with the product.

1.

Align the plug at the base of the cooling fan with the connector on the system board.

2.

Slide the cooling fan into the securing slots until the tabs lock into place.

3.

Close the system.

Cooling-fan assembly

Removing the cooling-fan assembly

CAUTION: Many repairs may only be done by a certified service technician. You should only perform

troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or

telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your

warranty. Read and follow the safety instructions that came with the product.

1.

If installed, remove the front bezel.

2.

Turn off the server modules using the operating system commands or the CMC.

3.

Turn off the enclosure, including any attached peripherals, and disconnect the enclosure from the electrical outlet

and peripherals.

4.

To reduce the chassis weight, remove the following (if required):
a. hard drives
b. server modules