Qmark QCH - Ceiling Mounted Fan-Forced Heaters User Manual

U series, Installation & maintenance instructions, Fan forced ceiling mounted heaters

Advertising
background image

U Series

Fan Forced Ceiling

Mounted Heaters

Dear Owner,
Congratulations! Thank you for purchasing this new heater manufactured by Marley Engineered Prod-

ucts. You have made a wise investment selecting the highest quality product in the heating industry. Please

carefully read the installation and maintenance directions shown in this manual. You should enjoy years

of efficient heating comfort with this product from Marley Engineered Products... the industry’s leader in

design, manufacturing, quality and service.

... The Employees of

Marley Engineered Products

Read Carefully -

These instructions are written to help

you prevent difficulties that might arise during installation of

heaters. Studying the instructions first may save you con-

siderable time and money later. Observe the following pro-

cedures, and cut your installation time to a minimum.

1. To prevent electrical shock, disconnect all power coming to

heater at main service panel before wiring or servicing.

2. All wiring must be in accordance with the National and Local

Electrical Codes and the heater must be grounded as a pre-

caution against possible electric shock.

3. Verify the power supply voltage coming to heater matches the

ratings printed on the heater nameplate before energizing.

4. Do not operate heater without grille installed.

5. Do not insert or allow foreign objects to enter any ventilation or

exhaust opening as this may cause an electric shock, fire,or

damage to the heater.

6. To prevent a possible fire, do not block air intakes or exhaust

in any manner. Keep combustible materials, such as crates,

drapes, etc., away from heater.

7. A heater has hot and arcing or sparking parts inside. Do not

use it in areas where gasoline, paint, or flammable liquids are

stored.

8. This heater is intended for ceiling installation only, at least 6

feet off the floor. Do not install in walls, floor, or other loca-

tions. Do not install closer than 12” to adjacent walls.

9. Use this heater only as described in this manual. Any other

use not recommended by the manufacturer may cause fire,

electric shock, or injury to persons.

10. This heater is not approved for use in hazardous locations as

described by the National Fire Protection Association (NFPA)

nor in corrosive atmospheres such as marine, green house, or

chemical storage areas.

Installation & Maintenance Instructions

SAVE THESE INSTRUCTIONS

WARNING

1

!

Nameplate

Model No.

U1000
U1500
U2004
U2007

Catalog No.

QCH1101
QCH1151
QCH1202
QCH1207

Watts

1000
1500
2000
2000

Volts

120
120
240
277

FILE#E21609