Characteristics, Warranty – Qmark Thermostats and Controls User Manual

Page 2

Advertising
background image

1- Press on PGM button to access the programming mode.

2- Press on Day button 3 seconds to select every day of the week.

3- Press on Hour and Min buttons to enter 6:15 AM, Prog. 1 ( ).

4- Press on PGM button to select Prog. 2 ( ) and Hour and Min buttons to

enter 8:15 AM.

5- Repeat step 4 to enter Prog. 3 (5:00 PM) and Prog. 4 (10:00 PM).

NOTE : When making modifications, make sure you are in the right

program.

Temporary or permanent temperature bypass

This operation allows you to temporarily modify the room temperature while you
are in the Automatic mode. Simply press on or button to select the desired
temperature, or the or button to select the Comfort or Econo settings you
have programmed.This temperature will be maintained until the beginning of the
next programmed schedule.

You can also switch to the Vacation setting for a prolonged absence by pressing
on and at the same time.The display will show icon. In that case,
the derogation is permanent. To return to the normal operating mode, press on
Mode button.

If you wish to immediately return to the programmed settings, press on Mode
button twice.

To modify the Saturday and Sunday schedules:

6- Press on Day button until SA or SU is displayed.

7- Press on PGM button to select Prog. 1 ( ) and Hour and Min

buttons to enter 7:30 AM.

8- Press on PGM button to select Prog. 2 ( ) and then Clear button to

erase it.

9- Press on PGM button to select Prog. 3 ( ) and then Clear button to

erase it.

10- Press on PGM button to select Prog. 4 ( ) and then Hour and Min

buttons to enter 11:00 PM.

11- Press on Mode button to exit this function.

a) To Program your Schedule

1- Press on PGM button to access the programming mode.

2- Press on Day button to select the day to be programmed. You can select

all days of the week by pressing on Day button for 3 seconds.

3- Press on PGM button to select program 1, 2, 3 or 4.

4- Press on Hour and Min buttons to program the time.

5- When you have completed your programming, press on Mode button

to exit this function.

b) To Erase a Program :

Select the program using PGM and Day buttons, and press on Clear
button. The time field displays --:-- when the program is inactive.

c) Example 1 : Comfort period from 7:00 AM to 10:30 PM

Economy period from 10:30 PM to 7:00 AM
Identical schedule for all days of the week.

1- Press on PGM button to access the programming mode.

2- Press on Day button 3 seconds to select every day of the week.

3- Press on Hour button to enter 7:00 AM, Prog. 1 ( ).

4- Press on PGM button again to select Prog. 2 ( ), and press on

Hour and Min buttons to enter 10:30 PM.

5- Press on Mode button to exit this function.

Schedule programming

The TH110A-DP-P allows 4 setting changes for each day of the week. There are
no pre-set programs.The programs are tailored to perfectly adapt to your life
style. The principle is very simple. For each day, enter the time at which you wake
up (P1), the time you leave for work (P2), the time you arrive back home (P3) and
the time you go to bed (P4).

Mode

For savings to be obtained, you must lower the temperature for a period of 2 to 3
times the delay required to bring the temperature back to your comfort level.

Example : If your system takes one hour to go from your saving temperature level
to your comfort temperature Ievel, it is useless to lower the temperature for a
period less than 2 to 3 hours.

Program

1

2

3

4

Time

Wake-up time

Leaving time

Return time

Bed time

d) Example 2 : Comfort period: Monday to Friday from 6:15 AM to

8:15 AM and from 5:00 PM to 10:00 PM.
Saturday & Sunday from 7:30 AM to 11:00 PM.

NOTE :

It is faster to program the same schedule for every day and then

modify the exception days.

CHARACTERISTICS

• Model:

TH110A-DP-P (240 VAC)

• Supply:

240 VAC, 50/60 Hz

• Load:

16.67 A maximum (resistive only)

• Power:

4000 watts (NI) @ 240 VAC

• Approvals:

CSA / UL

• Display range:

0 to 60 °C (32 to 140 °F)

• Setting range:

5 to 30 °C (40 to 85 °F)

• Comfort default setting:

20 °C (68 °F)

• Econo default setting:

18 °C (64 °F)

• Vacation default setting:

10 °C (50 °F)

• Storage:

-20 to 50 °C (-4 to 120 °F)

WARRANTY

All products manufactured by Marley Engineered Products are warranted against
defects in workmanship and materials for one year from date of original installa-
tion or 18 months from date of manufacture, except special components as noted
below which are warranted against defects in workmanship and materials (see
medallion levels below) from date of installation.This warranty does not apply to
damage from accident, misuse or alteration; nor where the connected voltage is
more than 5% above the nameplates voltage; nor to equipment improperly
installed or wired or maintained in violation of the products installation instruc-
tions. All claims for warranty work must be accompanied by proof of the installa-
tion or purchase.

The customer shall be responsible for all costs incurred in the removal or rein-
stallation of products, including labor costs and shipping costs incurred to return
products to Marley Engineered Products Service Center. Within the limitations of
this warranty, inoperative units should be returned to the nearest Marley author-
ized service center or the Marley Engineered Products Service Center and we will
repair or replace, at our option, at no charge to you with return freight paid by
Marley. It is agreed that such repair or replacement is the exclusive remedy avail-
able from Marley Engineered Products. If the product requires replacement, but
an identical model is no longer available, Marley Engineered Products will select
a comparable item.

the above warranties are in lieu of all other warranties expressed or implied and
all implied warranties of merchantability and fitness for a particular purpose which
exceed the aforesaid expressed warranties are hereby disclaimed and excluded
from this agreement. marley engineered products shall not be liable for conse-
quential damages arising with respect to the product, whether based upon negli-
gence, tort, strict liability or contract.

Some states do not allow the exclusion or limitation of incidental or consequen-
tial damages, so the above exclusion or limitation may not apply to you. This war-
ranty gives you specific legal rights and you may also have other rights which vary
from state to state.

For the address of your nearest authorized service center, contact Marley

Engineered Products in Bennettsville, SC, at

1-800-642-4328

.

Merchandise returned to the factory must be accompanied by a return authoriza-
tion and service identification tag, both available from Marley Engineered
Products. When requesting return authorization, include all numbers shown on
the products.

05/02/02 920-110-005-00-1-0 2/3

To program your settings

a)

To program the Comfort temperature, select the desired degree using the

buttons and press the button until the icon is displayed

(app. 3 seconds).

b)

To program the Economy temperature, select the desired degree using the

buttons and press the button until the icon is displayed

(app. 3 seconds).

c)

To program the Vacation temperature, select the desired degree using the

buttons and press on the and buttons simultaneously

until the icon is displayed (app. 3 seconds).

d)

Press the Mode button to exit this function and return to the normal
operating mode.

Schedule/Day

PROG. 1

PROG. 2

PROG. 3

PROG. 4

MON.

6:15 AM

8:15 AM

5 PM

10 PM

TUES.

6:15 AM

8:15 AM

5 PM

10 PM

WED.

6:15 AM

8:15 AM

5 PM

10 PM

THU.

6:15 AM

8:15 AM

5 PM

10 PM

FRI.

6:15 AM

8:15 AM

5 PM

10 PM

SAT.

7:30 AM

---

---

11 PM

11 PM

SUN.

7:30 AM

---

---

Advertising