General

The HT500 Utility Heater is designed for horizontal wall
mounting only. The built-in thermostat allows for adjustment
of the heat output from 40˚ to 70˚ F. The heater is factory
wired for use at 240/208 volts but can be re-wired for use at
120 volts.

Installation

1. Remove the grille cover by removing the 2 screws on the front

of the cover.

2. Position the heater on wall at desired mounting location main-

taining the minimum clearances as noted in Warning 3 and as
shown in Figure 1.

NOTE: The heater MUST be mounted horizontally to allow air

flow freely upward through the heating element.
Thermostat can be located towards either end of heater.

3. Securely fasten the heater to the wall with screws or bolts

using the four (4) pre-drilled holes in the heater back.

Wiring

1. Bring power supply cable to heater and install into heater

wiring compartment through the pre-punched 7/8” (22mm)
hole in the end of control box. Be sure to use cable clamp on
cable as required by the National Electric Code.

2. Connect the supply ground wire to the heater using the green

colored ground screw.

3. To operate the heater at 208 through 240 volts, connect

power supply wiring to heater wiring following the wiring dia-
gram shown in Figure 2. DO NOT USE THE WHITE WIRE
MARKED “N” FOR WIRING TO 208 THROUGH 240 VOLTS.

4. To operate the heater at 120 volts requires the heater to be re-

wired as shown in Figure 3 by connecting blue L2 lead wire to
wire connection of the other element blue lead wire and ther-
mostat blue lead wire. Remove the L2 wire marker. Connect
120 volts to the black L1 lead and the white N lead. See
Figure 3.

5. Complete the installation by replacing the grille cover using 2

screws removed earlier and 4 additional screws from parts
bag. Remove thermostat knob from the parts bag and install.

Heater Operation

1. Turn on the power supply to the heater.
2. Rotate the thermostat clockwise to the warmest setting. If the

air temperature is below 70˚F the heater should come on and

in a few moments the heating element will become warm. If
the air temperature is above 70˚F, the heater will not operate.
A check of the thermostat setting has to occur when the air
temperature is below 70˚F

3. The thermostat range is from 40˚F at full counterclockwise

position to 70˚F at full clockwise. Position thermostat at
desired location. Thermostat will automatically cycle the
heater on and off to maintain the desired temperature.

NOTE: The heater is designed to provide freeze protection and

the thermostat may allow the heater to come on at the lowest
setting if the space temperature drops below 40˚ F.

Cleaning and Maintenance

This heater requires no maintenance. Periodic cleaning to
remove accumulated dust and dirt is recommended. This
should be done using a vacuum with brush. See Warning 1.

2

12”min.

(304mm)

18”min.
(456mm)

End
View

Floor

Ceiling

Heater

21”

(532mm)

16”
(405mm)

1.75 ”
(44
mm)

(51
mm)

2”

5”

(127

mm)

N

L1

T’Stat

Blue

Black

Blue

White

Element

Blue

Blue

Blue

Blue

T-Stat

Blue

White

Black

L2

HT500 - Factory wired for 240/208 volt operation

500 watts, 2.1 amps @ 240 V
375 watts, 1.8 amps @ 208 V

HT500 - Field re-wired for 120 volt operation

500 watts, 4.2 amps

To

240/

208 V
Supply

To

120 V

Supply

Do not use white wire in 240 volt circuit

Figure 2

Figure 1

Figure 3

Element

N

L1

To rewire for 120 volt
operation:

1. Connect Blue “L2”

wire connection to
other element Blue
lead and thermostat
Blue lead. Remove
“L2” wire marker.

2. Connect 120 volts to

Black “L1” & White
“N”.

LIMITED WARRANTY

All products manufactured by Marley Engineered Products are warranted
against defects in workmanship and materials for one year from date of instal-
lation, except heating elements which are warranted against defects in work-
manship and materials for five years from date of installation. This warranty
does not apply to damage from accident, misuse, or alteration; nor where the
connected voltage is more than 5% above the nameplate voltage; nor to
equipment improperly installed or wired or maintained in violation of the prod-
uct’s installation instructions. All claims for warranty work must be accompa-
nied by proof of the date of installation.

The customer shall be responsible for all costs incurred in the removal or rein-
stallation of products, including labor costs, and shipping costs incurred to
return products to Marley Engineered Products Service Center. Within the lim-
itations of this warranty, inoperative units should be returned to the nearest
Marley authorized service center or the Marley Engineered Products Center,
and we will repair or replace, at our option, at no charge to you with return
freight paid by Marley. It is agreed that such repair or replacement is the exclu-
sive remedy available from Marley Engineered Products.

THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES
EXPRESSED OR IMPLIED. AND ALL IMPLIED WARRANTIES OF MER-
CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH
EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY
DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT. MARLEY
ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUEN-
TIAL DAMAGES ARISING WITH RESPECT TO THE PRODUCT, WHETHER
BASED UPON NEGLIGENCE, TORT, STRICT LIABILITY, OR CONTRACT.

Some states do allow the exclusion or limitation of incidental or consequential
damages, so the above exclusion or limitation may not apply to you. This war-
ranty gives you specific legal rights, and you may also have other rights which
vary from state to state.

For the address of your nearest authorized service center, contact Marley
Engineered Products in Bennettsville, SC, at 1-800-642-4328. Merchandise
returned to the factory must be accompanied by a return authorization and
service identification tag, both available from Marley Engineered Products.
When requesting return authorization, include all catalog numbers shown on
the products.

9/96

Part No. 5200-2314-000

SWO 308

Side
view

.203”diameter holes

(5mm)

470 Beauty Spot Rd. East
Bennettsville, SC 29512 USA

Advertising