Qmark Low-Profile User Manual

Lp series, Installation, operation & maintenance instructions, Low profile air curtains

Advertising
background image

LP Series

Low Profile Air Curtains

Read Carefully -

These instructions are written to help you

prevent difficulties that might arise during installation of the unit.
Studying the instructions first may save you considerable time
and money later. Observe the following procedures, and cut
your installation time to a minimum.

CAUTION - TO REDUCE RISK OF FIRE AND ELECTRIC
SHOCK OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufac-

turer. If you have questions contact the manufacturer.

2. Before servicing or cleaning the unit, switch power off at

service panel and lock service panel to prevent power from
being switched on accidentally.

3. Installation work and electrical wiring must be done by qual-

ified persons in accordance with all applicable codes and
standards, including fire rated construction.

4. When cutting or drilling into wall or ceiling, do not damage

electrical wiring or other hidden utilities.

5. Make certain that the power source conforms to the electri-

cal requirements of the unit (check nameplate). Disconnect
power before installing or servicing. Lock it in the open posi-
tion and tag it to prevent unexpected application of power.
Failure to do so could result in fatal electric shock.

6. All wiring should be done by a qualified electrician, using

copper wire only and in accordance with the National
Electric Code (NEC), all applicable local codes, and ordi-
nances, and all sections of this manual. Any variance voids
the warranty and may create unsafe conditions.

7. Special attention must be given to any grounding informa-

tion pertaining to this product. To prevent the risk of elec-
trocution, the unit must be securely and accurately
grounded. This should be accomplished by connecting a
grounded conductor between the service panel and the
grounding lug provided in the wiring compartment.
To ensure proper ground, the grounding means must be
tested by a qualified electrician.

8. Do not insert fingers or foreign objects into the air curtain.

Do not block or tamper with in any matter while in operation.
Do not touch it while in operation or just after it has been
turned off, as some parts may be hot enough to cause
injury.

9

This product must NOT be used in potentially dangerous
areas such as hazardous locations, flammable, explosive,
chemical-laden, or wet atmospheres are present.

10. To reduce the risk of fire or electric shock, do not use this

air curtain with any solid state speed control devices.

SAVE THESE INSTRUCTIONS

!

GENERAL

Marley air curtains produce a wall of continuously flowing air that acts as a thermal barrier against outside air and flying insects.
These air curtains maintain interior conditioned temperature and prevent heated or cooled air from escaping through open door-
ways. They reduce humidity and loss of cold air when used over freezer and cooler doors. High traffic area doors can be left open,
eliminating wear and nuisance of opening and closing automatic and manual doors used over service entrances, access doors, etc.
Air curtains provide protection against insects, dust, odor, fumes and other contaminants.

Installation, Operation & Maintenance Instructions

WARNING

Refer to Specifications
Dimension “A”, page 2

Note – All dimensions are the same for all low-profile
series air curtains. Model number indicates width of
unit. (Example LP4800 indicates 48” wide unit.)

7”
178 mm

8

7

/

8

223 mm

Advertising