Unpacking, Installation, Electrical connections – Qmark Low-Profile User Manual

Page 2

Advertising
background image

Specifications

UNPACKING

1. With packaged unit on floor, carton arrows should point

upward.

2. Carefully remove staples from top of carton and fold back

sides.

3. Carefully remove cabinet by lifting out unit and place on work

surface.

4. Remove four (4) phillips screws securing mounting bracket

and remove unit mounting bracket.

INSTALLATION

1. Determine mounting location utilizing unit mounting bracket

and attach unit mounting bracket using appropriate mounting
hardware (not included).

IMPORTANT: The hardware and the supporting structure must
be capable of supporting a minimum 150 lb. load.

NOTE: All installation should be done to meet local building
codes.

2. Mount air curtain cabinet assembly by simply “hanging” unit

onto unit mounting bracket by aligning vertical tabs with air
curtain cabinet assembly slots (Figure 2). Secure air curtain
to mounting bracket by four (4) phillips screws.

ELECTRICAL CONNECTIONS

Cord Connected

1. Connect power per nameplate to correct power supply.

2. Install all wiring, protection, and grounding in accordance

with the National Electrical Code (NEC) and all requirements.

3. Unit is ready for operation.

4. Confirm unit is operating within all electrical and performance

specifications.

NOTE: Air curtain has high/low selector switch that is factory
wired

THIS FAN HAS AN INTERNAL SELF-RESETTING THERMAL
OVERLOAD PROTECTOR. ALWAYS DISCONNECT FROM
POWER SUPPLY BEFORE SERVICING.

ALL AIR CURTAINS SHOULD BE INSTALLED BY QUALIFIED
PERSONNEL.

DO NOT ATTEMPT TO LIFT THIS AIR CURTAIN BY ITS
LOUVER OR DAMAGE MAY RESULT.

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO
NOT USE THIS AIR CURTAIN WITH ANY SOLID STATE
SPEED CONTROL DEVICES.

THIS PRODUCT MUST NOT BE USED IN POTENTIALLY
DANGEROUS AREAS SUCH AS HAZARDOUS LOCATIONS,
FLAMMABLE, EXPLOSIVE, CHEMICAL-LADEN, OR WET
ATMOSPHERES ARE PRESENT.

DO NOT DEPEND UPON A THERMOSTAT OR OTHER
SWITCH AS THE SOLE MEANS OF DISCONNECTING
POWER WHEN INSTALLING OR SERVICING THE UNIT.
ALWAYS DISCONNECT AND LOCK OUT POWER AT THE
MAIN CIRCUIT BREAKER AS DESCRIBED ABOVE.
FAILURE TO DO SO COULD RESULT IN FATAL ELECTRIC
SHOCK.

2

AIR DELIVERY

Dim.

Avg. FPM

CFM

Total

Max

Model No.

“A”

at Nozzle

at Nozzle

HP

Amps

Volts

LP36001115

37.0

1800/1350

1295/971

1/15

1.3A

120

LP42001110

42.0

1800/1350

1470/1103

1/10

1.6A

120

LP48001108

48.0

1800/1350

1681/1260

1/8

2.1A

120

LP60001108

60.0

1800/1350

2102/1576

1/8

2.1A

120

LP36001208

37.0

1800/1350

1295/971

1/8

0.7A

240

LP42001208

42.0

1800/1350

1470/1103

1/8

0.7A

240

LP48001206

48.0

1800/1350

1681/1260

1/6

1.0A

240

LP60001206

60.0

1800/1350

2102/1576

1/6

1.0A

240

Figure 1

Figure 2

Fit tab of mounting bracket into

slot on back of unit as shown

Screw holes (4)

Mounting bracket

Mounting holes

(10 total)