Operation

1.After power has been connected to unit, fans will start

in either preset (high/low) speed selection.

2.Air velocity is controlled by selection of high or low

speed indicator. This feature allows the setting of air
velocity to individual desired performance and energy
efficiency.

3.Air direction at outlet can be controlled by adjustable

vanes at the nozzle which compensates for possible
draft conditions.

NOTE: Air direction settings shown in Figures 6 & 7.

NOTE: Cold air will try to escape near floor level.
Warm air will try to penetrate curtain near top of
doorway. Air flow can be controlled by direction of
nozzle louvers and by high/low settings.

4.For multiple unit applications (wide openings), mount

units a minimum of 3” apart to allow for proper air
intake and discharge.

Maintenance

WARNING: ALL ELECTRIC POWER MUST BE
DISCONNECTED WHEN INSTALLING OR SERVICING
THIS EQUIPMENT. MORE THAN ONE DISCONNECT
SWITCH MAY BE REQUIRED TO REMOVE POWER
FROM THE UNIT.

LUBRICATION

Ball bearings are permanently lubricated and require no
further lubrication.

CLEANING

1. The air door cabinet may be wiped off with a damp

cloth. Do not allow motor to get wet. Do not use sol-
vents or harsh detergents.

NOTE: Keep air intake louvers clear of dirt and dust
accumulation which could affect performance.

2. Check blower wheels for accumulated dirt twice a year

and clean. If disassembly is required, see GENERAL
SERVICING section.

GENERAL SERVICING

WARNING: IF SERVICING IS REQUIRED, IT SHOULD
BE DONE BY QUALIFIED PERSONS ONLY.

WARNING: ALWAYS DISCONNECT POWER SUPPLY
BEFORE SERVICING.

1.To remove motor/blower heater assembly,

repeat steps 4, 5 and 6 in Unpacking section.

2. Place motor/blower assembly on workbench.

3. To replace blower wheel, remove the three slotted hex

head screws on outer blower ring assembly (See
Figure 8, Replacement Parts Illustration.) The wheel
is held onto shaft by two hex head screws.

NOTE: To re-assemble repeat steps 4 & 5 in
installation section page 3.

IMPORTANT: NOTE POSITION OF WHEELS TO
PREVENT RUBBING WHEN REPLACED.

4. To remove motor:

a. Remove blower wheels. (See Step 3 above.)
b. Remove blower scrolI (six hex head screws).
c. Unscrew and remove motor mounts.

5. Replace motor/blower.

Figure 6 - Desired Air Flow
Adjustment for Temperature and
Humidity Control.

Figure 7 - Desired Air Flow Adjustment