Important Note: The portion of the sensing tube that attaches to

the blower has an opening that must face the blower and be posi-

tioned near the center of the blower inlet. This should not be

removed or disturbed during the romoval and reinstallation of the

blower assembly into the cabinet. After reasembly, check to make

sure this sensing tube has not been damaged or dislodged. In the

control compartment, the sensing tube attaches to the “LOW” port

on the pressure differential switch.

When powering the unit for the first time, always check the wiring

for correctness and tightness, make sure the power supply

matches the nameplate rating of the unit, make sure the sensing

tubes of each PD switch are in the proper position and location

and all the cabinet compartment covers are closed. It is also rec-

ommended that the front grille covers should be in place. This will

make sure the pressure switch will sense enough vacuum and

turn on heater.

UNPACKING

For Single Cabinet Units: 36”, 42”, 48” and 60”
1. With packaged unit on the floor, carton arrows should point

upward.

2. Carefully remove staples from top of carton and fold back sides.
3. Carefully remove cabinet from carton by lifting out unit using fin-

ger holes in styrofoam side inset and place on work surface.

CAUTION: Do not attempt to lift this air curtain by its louver or

damage may result.

4. Unscrew six (6) knurled nuts and remove air intake grille. (See

Figure 3)

5. Carefully disconnect motor electric cord from socket and plug

assembly and remove two wing nuts on blower base. (See

Figure 4)

6. Carefully disconnect pressure switch hose quick connector at

blower by holding body of connector and pushing the release

ring towards the center of connector while pulling the hose to

disconnect.

7. To remove motor blower assembly, lift from rear of motor hous-

ing to prevent damage and misalignment to shaft and blower

wheels. Once the motor/blower assembly is removed, the heater

assembly will be accessed.

NOTE: After unpacking unit, inspect carefully for any damage that

may have occurred during transit. Check for loose, missing or dam-

aged parts. The hinged cabinet wiring compartment cover should

also be opened to inspect the components and wiring inside.
8. Make sure the open coil elements do not touch any metal part

and all the porcelains holding the elements are not broken and

are in their proper place.

For 2 Cabinet Units: 72”, 84” and 96” See Figure 5, Page 5
1. With packaged units on the floor, carton arrows should point

upward. Cartons are marked A & B.

2. Follow Steps 2 through 8 for Single Cabinet Units.
NOTE: Cabinet A (left), Cabinet B (right). Carton labeled

Cabinet B will contain the Main Control Box and all harness

wires and parts bag to interconnect the two cabinets.
For 3 Cabinet Units: 108”, 120”, 132” and 144”

See Figure 6, Page 6
1. With packaged units on the floor, carton arrows should point

upward. Cartons are marked A, B and C.

2. Follow Steps 2 through 8 for Single Cabinet Units.
NOTE: Cabinet A (left), Cabinet B (center), Cabinet C (right).

Carton labeled Cabinet C will contain the Main Control Box

and harness wires and parts bag to interconnect the three

cabinets. Cabinet B may also have harness wires to inter-

connect to Cabinet A.

INSTALLATION

For Single Cabinet Units:

NOTE: All installation should be done to meet local building codes.
1. Using template provided, determine mounting location.
2. Drill holes and attach mounting hardware (not included).
3. Mount cabinet on wall and securely tighten hardware.
4. Replace motor/blower assembly in cabinet. Pass pres-

sure switch hose through proper hole on blower base.

Reconnect motor electric cord plug assembly.

5. Attach pressure switch hose to quick connector at right

blower housing.

6. Secure two wing nuts on blower base.

Figure 3

Figure 4

!

WARNING

MAKE SURE NO COMBUSTIBLE MATERIAL NOR ANY

OTHER FOREIGN MATERIAL FALLS ON THIS HEATING

ELEMENT CAVITY WHILE IT IS EXPOSED WITH THE

MOTOR/ BLOWER ASSEMBLY OUT OF THE CABINET

CAUTION

!

THE HARDWARE AND THE SUPPORTING STRUCTURE MUST

BE CAPABLE OF SUPPORTING A MINIMUM 150 LB LOAD.

Figure 3: Sensing Tube Location

Quick connector

Sensing tube location