Installation of your Marley product is easy. No special technical knowledge
is needed. Only a few ordinary tools are required:

Screwdriver
Hammer
Saber saw, Keyhole saw, or Jig saw
Electric drill with bit
Wire cutters
Wire stripper
Wire nuts and general electrical supplies
Safety glasses
Ruler and straight edge

All hand tools should be insulated. Power tools should display the UL
Listing Mark.

NEW HOME INSTALLATION

1. Cut round or square hole in sheathing at desired location in wall.

Round holes should be 11 1/8” in diameter. Square holes should be 11
1/8” on a side. (See Figure 2.)

2. Install door and outside sleeve assembly from outside. Caulk and level

assembly before nailing door frame tight. Remove tape, permitting
damper door to open. House insulation can be worked around sleeve.
(See Figure 3.)

3. Working from inside the house, slide inside sleeve into place

temporarily. Determine whether to remove one or both knockouts from
outside sleeve, permitting outlet box to drop through. Remove
knockouts from outside sleeve. (See Figure 4.)

4. Slide inside sleeve into place again, and pull power cable through

outlet box opening. This will determine length of power cable to
ventilator. Attach cable to outlet box, using an approved connector.
Splice cable to switch and receptacle leads in outlet box cover.
Ground wire may be attached to grounding bolt in outlet box.

5. Adjust inside sleeve so that flange will be flush with finished wall. Using

metal screws, fasten inside housing to outside housing. Screws are
provided with ventilator.

6. Push outlet box and outlet cover into place and fasten with screws.
7. Remove chain from envelope and attach it to slotted hole in end of

chain spring on inside of door. Feed chain through chain guides and
over switch lever.

8. Install motor blade assembly. Keyhole slot in motor bracket should be

kept on top of ventilator. Insert bottom of motor bracket into holes in
outlet box cover. Engage keyhole slot over screw in top of ventilator
and tighten, making sure that blade is centered in sleeve.

9. Push switch lever down to prevent motor from starting and insert plug

into receptacle. Be sure fan blade does not strike cord. When switch
lever is released, motor will start.

10. Feed chain through hole in motor bracket and slot in grille and attach

grille to ventilator with knob. Obtain pendant from envelope and slide it
onto chain. Attach small sleeve or coupling to end of chain and pull
pendant against it.

11. To shut off ventilator, pull chain taut and swing to the left to secure it in

hook.