3
AIR DISCHARGE
OUTLET
OUTLET
BOX COVER
GRILLE
MOUNTING
TABS
BLOWER UNIT
GRILLE
12 1/2”
11 13/16”
7 5/8”
10”
11 1/2”
GRILLE
SPRING
BLOWER
MOUNTING
SCREWS
WIRE
CONNECTORS
MODELS:
7100A & 7150A
OUTLET
BOX COVER
GRILLE MOUNTING
TABS
BLOWER
UNIT
GRILLE
12 1/2”
12 1/2”
11 3/16”
7 5/8”
10”
GRILLE
SPRING
BLOWER
MOUNTING
SCREWS
REFLECTOR
MOUNTING
SCREW
REFLECTOR
ASSEMBLY
MODELS:
7100LA & 7150LA
FIG. 3
MOUNTING
BRACKETS
MOUNTING
BRACKETS
WIRE
CONNECTOR
(PLUG)
WIRE
CONNECTOR
(PLUG)
AIR DISCHARGE
OUTLET
WIRE
CONNECTORS
INSTALLATION IN EXISTING HOMES
(MODELS: 7100A, 7130A, 7150A, 8090A,
8100A, 7100LA, 7150LA, 8090LA & 8100LA)
1. Carefully read all previous installation instructions and follow
those applicable to your installation, including ducting and
wiring. (Figs. 1 & 2.)
2. Drill a small hole in the ceiling from below in proposed location,
then locate this hole in the attic (or crawl space).
3. In attic, mark ceiling for cutout by using housing as a template.
Using this line, make a cutout about 1/4” larger.
4. Place housing with mounting brackets installed into hole and
rest mounting brackets on sheetrock. Extend and nail all four
ends of mounting brackets.
5. Perform steps 1 through 10 as for new construction.
FIG. 5
1”