Remote Character Set

The character sets shown in your self-test printout may also be selected

remotely if performed under program control. Character set selection

commands override the Operator Control Panel configuration setting

(except under power-on or reset conditions). When taken “off-line,”

the printer remains in the character set last commanded. See the

HP256X Printer Family Technical Reference Manual, 02564-90905, for

information on remote character set selection.
Standard ASCII SHIFT-IN and SHIFT-OUT codes may be used to select

primary and secondary character sets. SHIFT-OUT selects the secondary

set and SHIFT-IN returns the printer to the primary set. Any number

of character sets may be used within one print line if they are the same

pitch. Additionally, bar codes and line draw can be printed on the same

line as 10 character-per-inch (cpi) character sets. (Compressed character

sets and the double-high/double-wide character set cannot be printed on

the same line with each other or with 10 cpi text.)

Select Page Length

Representation:

FUNCTION 7

Page length can be selected in either lines-per-page or in ^ inch

increments. Refer to “Adjusting Forms Length” on page 3-25 for

instructions on how to set the CONFIGURATION mode.

Disconnect Modem:

FUNCTION 50

If a serial interface is installed in the printer and is connected to a

modem, it is possible to disconnect the modem from the printer’s

Operator Control Panel. Setting function 50 to parameter “1” and then

pressing

(

enter

!

makes the Data Terminal Ready line to go to the

“OFF” state for two seconds. If the modem Data Terminal Ready line is

connected, this action should disconnect (hang-up) the modem.

Difficult Forms Mode:

FUNCTION 51

Some complex multi-part forms such as statement mailers or invoices

may result in a loss of the Top of Form position. If this problem occurs,

the printer can be placed in a low speed, high torque mode by accessing

function 51 of the CONFIGURATION mode and selecting parameter

“1.” Since this will affect throughput, make sure function 51 is set back

to “0” when the high torque mode is not required.

Horizontal Graphics

Density Selection:

FUNCTION 52

Horizontal graphics density (60 or 70 dots per inch) is selected via

function 52. There is not a parameter “1” or “0” for this function. Only

60 or 70 shows up in the display window. Programmatically setting

the density overrides the operator control panel setting except under

power-on or reset conditions. Default value is 70 dots-per-inch (dpi).