beans deposit more oils into the brewing chamber. When this
happens you can manually start a tablet cleaning cycle as follows:

READY

Push the rotary dial, until the display shows

RINSE

.

• Push the rotary dial again and turn it until the display shows

CLEAN

.

• Push the rotary dial again to confirm that you want to use this

program now. The display shows

EMPTY TRAY

.

• Continue with the steps 2 through 9 of chapter 18.1.

The machine will reset itself and will remind you after the next
200 cups of coffee to repeat this cycle.

18.3 DECALCIFYING /

DE-SCALE READY

The machine has an integrated decalcifying program. This program
takes about 40 minutes.
When the display shows

DE-SCALE / READY

it is time to

decalcify the machine. The Rinse button is illuminated. You can
still make coffee. However, it is highly recommended decalcify-
ing the machine within the next 3 to 4 days.
Important CLEARYL FILTER: If you use the Clearyl water
cartridge and the display shows

DE-SCALE / READY

, then your

cartridge function was not activated. Follow the instructions in
chapter 15.1 to activate a new cartridge.
Important: The decalcifying program must not be interrupted.
DECALCIFYING AGENT: Only use our special decalcifying
tablets Model # 61848, chapter 25.
CAUTION: Never use vinegar or any other decalcifying agent.
This might damage internal parts of the machine.
CAUTION: Immediately remove any splashes or drops of the
decalcifying solution from sensitive surfaces, such as natural

stone or wood. Always wait until the decalcifying solution in the
water tank has been used up. Do not fill additional decalcifying
solution into the water tank.

DE-SCALE READY

and the Rinse button is illuminated.

1. Push the Rinse button. The display shows

EMPTY TRAY

.

Attention: If the tray and the used coffee container are
already empty, you still need to remove the tray for approx.
20 seconds and then replace it.

AGENT IN TANK

.

2. Empty the Water Tank. The Clearyl filter should not be in the

water tank (see above).

3. Remove the frothXpress or the Dual Frother.
4. Dissolve 3 of the large square decalcifying tablets in a

container with 20 oz. of water (0.6 liters) and pour the solution
into the water tank.

5. Replace water tank.
6. Place a large container (at least 20 oz.) under the steam nozzle

(Fig. 18).

7. Push the rinse button. The display shows

DE-SCALING

. The

machine pumps the descaling solution through the system
and through the steam nozzle. During this operation, the
Rinse button blinks.

8. After approx. 15 minutes the action stops and the display

shows

EMPTY TRAY

.

9. Remove the container and then the drawer and tray.
10. Empty the drawer and the ground coffee container. Then

replace.

FILL WATER TANK

.

11. Remove the water tank, rinse it thoroughly and fill with up to

18 oz. of fresh cold water and replace.

PRESS RINSE

.

12. Place a large container (at least 20 oz.) under the steam nozzle

(Fig. 18) and press the rinse button.