#10 Sheetmetal screw

10-24 Machine screw

#25 or 9/64"

tap 10-24

#22 or 5/32"

pilot hole

Cutout per

(Caution: This installation is required on fire rated door openings with removable mullion.)

Door

Door frame

98 Strike

98 Strike locator

Mark and drill holes as necessary.

#7 for 1/4-20 machine screws,

For #14 self-drilling screws, no pilot

hole necessary

7/64" for 6-32 machine screws,

9/64" for #6 sheetemtal screws

(see fastener table)

99 strike

For mounting hole locations use Strike Locator (Template) provided.

DRILL CHART

Strike hook

Mullion post

STRIKE HOOK INSTALLATION

Door

Door

Shield (if necessary)

Shim (if necessary)

98 Strike

98 STRIKE INSTALLATION

Align the strike with

the latchbolt.

Firmly tighten screws

(when required)