Self Adjusting Reserve Capacity

Beginning reserve capacity is always 33% of total system bed maximum capability

The system recalculates the reserve capacity Daily (2:00 AM) based upon the consumers water

usage during the previous days and will adjust the reserve up or down 10% from the previous reserve setting
with a maximum reserve capacity of 50% of bed volume. This allows the system to change automatically to
meet your changing water conditioning requirements without program entries.

Calendar Day Override/Vacation Mode

The calendar day override with true variable brining assists in maintaining the bed during periods
of time of inactivity (i.e. vacations) without excessive salt and water usage.

Day override keeps bed fresh during inactive or low use periods by regenerating the calculated
bed volume used at preset day intervals.

Extra Cycle Button
Extra cycle button can be activated to regenerate the calculated bed volume that has been used immedi-
ately or delayed to 2:00 am the same night.

Upper And Lower Screens
The system is complete with upper and lower screens to protect the valve internals and plumbing fixtures
down line from media and/or debris.Lower distributor system with screen provides maximum use of resin
bed capacity with service flows

Mineral Resin Tank
The mineral tank has injected molded inlet for leak free seals, NSF approved inner lining for sanitation and
fiberglass wrapped exterior for strength – No metal or rust to corrode

Exterior Jacket (optional)
Makes for an attractive appliance and reduces exterior tank sweating in high humidity areas

High Capacity Resin
Delivers high effeciency salt and water usage, longer bed life and lower maintenance

Brine Tank is a high density Polyetheylene . It withstands impacts and retains its shape when full of salt

Dual Safety Brine Valve with over flow port eliminates potential overfilling and spilling onto the floor –
Note: The construction of the safety brine valve does not have solvents

High Flow 1” Bypass Valve with 1” mnpt Yoke
Has independent influent and effluent controls for clean start up and field diagnostic evaluations

Displayed Monitored System Values for easy-to-use trouble shooting and diagnostic evaluations

Time of Day
Capacity Remaining to Next Regeneration
Gallons Used Since Last Regeneration
Average Gallons Used
Flow Rate
Previous Days Usage
Days Since Last Regeneration