www.EWSWATER.com

4.3-6

Tank is completely filled when sound of water stops or

at a slow pace of 1-2 GPM it will take 5-10 minutes. Keep outlet side closed until later.

Inlet
Side:

Open
Position
once filled

SLOWLY OPEN - (as illustrated)
on inlet supply side only.
Keep outlet side closed.

SLOWLY OPEN -Completely open (preferred) Ball Valve or Gate
Valve on inlet supply side only.
Keep outlet side and bypass valves closed.

Inlet Side Open

STEP 1-B: TANK IS FILLED, OPEN INLET COMPLETELY

STEP 2: PLUG IN THE ELECTRICAL

Plug the 24 volt transformer into any unswitched electrical outlet or an acceptable extension to that outlet. Be sure that if
plugged into a GFI outlet that the outlet has been reset. Please inform the consumer of the need for an unswitched outlet
which can not be turned off and that GFI outlets need to be occassionally checked for operation. Please follow all applicable
local codes. If using an extension, make sure of a complete and secure connection. No spliced connections. Do not break
into wires with fasteners or staples. Make sure transformer has a snug and secure connection to outlet (larger units must use
set screws to secure transformer to outlet). Electrical is used to bring power to the digital valve, in order to keep the time and
operate the automatic backwash program. Cost of this operation is similar to the cost of a radio alarm clock.

Address Advancement Note:
Push and Hold Extra Cycle Button for approximately 5 seconds to advance the valve into Regeneration
Cycles. As each Regeneration Cycle is Entered a Red Dot will Illuminate on the left of the Regeneration
Cycle Title printed on the face panel.

To advance to the next Regeneration Cycle before it times out, Push the Extra Cycle Button once (Do Not
Hold) once the Number on the left of the Address Display stops flashing.

STEP 3:

BEGIN THE REGENERATION CYCLE STEPS AS
FOLLOWS FOR START-UP
THESE STEPS ARE CRITICAL FOR THESE
HIGHLY EFFICIENT METERED VALVES
PLEASE FOLLOW THE STEP BY STEP
INSTRUCTIONS