Begin the Regeneration Cycle Steps

as follows for Start-Up

·

Push and Hold Extra Cycle Button for approxi-
mately 5 seconds to advance the valve into regen-
eration and to the Tank Fill Address.

Tank Fill Display [ 1 - - - - 5.0 ]

Allow the Tank Fill to complete the Cycle and Con-
firm the water is being delivered into the Empty Brine
Tank. Allow the valve to advance to the next cycle with-
out assistance.

NOTE: While waiting for the Cycle to complete check
for leaks at Plumbing connections and Factory con-
nections which have been loosened during Shipping
and Handling.

1 - - - - 5.0

2 - - - 15.0

·

Brine Making Display [ 2 - - - 15.0 ]

Once the valve has Advanced into the Brine Making
Cycle wait until the number (2) stops flashing.

Push the Extra Cycle Button Once to advance Valve
to the next cycle.