Display Options

To toggle the displayed temperature scale between

Fahrenheit and Celsius, press the Enter button for at

least two seconds until the desired scale is displayed.

(Pressing Enter for less time will turn on the back-

light if it is off.) The desired scale will persist on the

display until this process is repeated or the FlexStat

is restarted.
After a restart, the temperature scale will revert to

whatever scale is set in the Application menu. To

change the scale so that it persists after restarting,

change it in the Application menu by resetting the

selected application to Not Configured, changing

the temperature scale, and then reconfiguring all the

application options. See

(Advanced) Application and

Additional Setup on page 7

).

Fahrenheit decimal values are not displayed by de-

fault but can be enabled in the User Interface menu.

See

Show Temperature Tenths (Decimals) on page

21

.

With R2.0.0.13 and later firmware, Fahrenheit tem-

perature values on the display change in whole

degree increments by default, and Celsius values

change in 0.5° increments. Changing the default No

to Yes will show tenths of a degree values for both

scales.
This does not affect setpoint adjustments, which are

always in whole degree increments for Fahrenheit

and half degree increments for Celsius.

WED 11/19

3:22 PM

COOL:

OCC:

FAN:

HUM: 37% RH

When Display Blanking is enabled, the display

turns off at the same time the backlight goes off

(after reset, initial power-up, or time-out). When any

button is pressed, the display will reappear until the

time-out is reached again. See

Display Blanking on

page 21

.

Hospitality mode has a simpler display and limited

menus, and it is typically used in hotel rooms. Users

typically can change only the setpoint, system mode,

and fan speed. Pushing the Left and Right buttons

displays customizable menu selections. See

Mode on

page 21

.

By default, rotation values in the lower right of the

screen show relative humidity and/or CO

2

levels in

models with the relevant optional sensors. If more

than one value is shown, the values will rotate ap-

proximately every five seconds.
These values can be hidden if desired, and additional

options are also available. See

Rotation Values on

page 21

.

NOTE: Displays can also be locked. Locked UI

mode appears like Standard mode on the

Home screen, but all button functions

(except the backlight) are disabled. The

setpoint and other operation functions

cannot be changed by the user. See

Mode on

page 21

.

NOTE: The contrast of the LCD display can also be

adjusted. See

Contrast on page 21

.

WED 11/19

3:20 PM

COOL:

OCC:

FAN:

HUM: 36% RH

COOL:

OCC:

FAN:

HUM: 36% RH

Date and Time Display are enabled by default, but

they can be turned off and replaced by a rotating

clock icon. See

Show Time and Date on page 21

.