28

Note installation setup number and setting changed from the factory settings.

Setup Number 3 - Changed to 1

Setup Number 5 - Changed to 9

Setup Number 9 - Changed to 5

Setup Number 12 - Changed to 1

Wiring diagram Fig .6 applies (Conventional 1 heating/1 cooling system with one transformer)

The thermostat can receive a battery to light the panel in case of a power failure. It serves no other
purpose and is not required for operation or restart after a power failure.

Time Delays Built Into the Thermostat

Pay attention to the various time delays built into the thermostat as explained in the Thermostat
Installation and Operating Instructions. The time delays are built-in to protect the Wine Guardian and
its components from damage due to short cycling.

Note

Any time the “cool on” indicator is flashing the unit is waiting for the timer in order to start.

Location of Supply and Return Grilles

Locate the supply and return grilles inside the cellar to create an airflow pattern that maximizes
air circulation in the room. Avoid short circulating of the air.

Do Not:

• Install the return air grilles directly on the floor as the grilles will collect dust from the

floor.

• Locate the supply or return air grille where it is blocked by bottles, boxes or cases.

• Locate the supply air grille where it blows directly on the thermostat.

Relocating a grille on the Wine Guardian

1) Remove the fasteners from the grille.
2) Remove the fasteners from the access door panel to be replaced by the grille.
3) Relocate the outlet grille to its new location and secure in place using its fasteners.
4) Replace the access door panel where grille was located.