Other miscellaneous problems – Vintage Cellars Wine Guardian Water-Cooled Cooling System User Manual
Page 50
![background image](/manuals/641375/50/background.png)
47
Humidity Too High When Unit is Not Running
Possible Cause
Solution
Unit needs to run to dehumidify
Run unit. Seal openings around doors (gasket and
sweep)
Humidity Too High When Unit is Running and Cooling
Possible Cause
Solution
Too much moisture in cellar
Poor vapor barrier installation
Humidifier malfunction refer to the
humidifier instructions.
Add dehumidifier to surrounding space
Other Miscellaneous Problems
Unit Operates but the Power Switch Light is not ON
Possible Cause
Solution
Bulb is burned out
Replace bulb
Unit is leaking water
Possible Cause
Solution
Trap plugged
Clean trap
Condensate pan plugged
Remove blockage and clean
Unit not level
Level with shims
Unit is Running Properly, but the Sound of Unit is Objectionable
Possible Cause
Solution
Noise is from airflow
Redirect airflow
Add baffles
Add insulated ductwork
Noise is from unit
Add sound baffle between unit and occupied
space