Humidity Too High When Unit is Not Running

Possible Cause

Solution

Unit needs to run to dehumidify

Run unit. Seal openings around doors (gasket and
sweep)

Humidity Too High When Unit is Running and Cooling

Possible Cause

Solution

Too much moisture in cellar

Poor vapor barrier installation
Humidifier malfunction refer to the

humidifier instructions.

Add dehumidifier to surrounding space

Other Miscellaneous Problems

Unit Operates but the Power Switch Light is not ON

Possible Cause

Solution

Bulb is burned out

Replace bulb

Unit is leaking water

Possible Cause

Solution

Trap plugged

Clean trap

Condensate pan plugged

Remove blockage and clean

Unit not level

Level with shims

Unit is Running Properly, but the Sound of Unit is Objectionable

Possible Cause

Solution

Noise is from airflow

Redirect airflow
Add baffles
Add insulated ductwork

Noise is from unit

Add sound baffle between unit and occupied

space