Installation of the Optional Wine Guardian
Remote Sensor
 
The Remote Sensor is a combination temperature and humidity 
sensor only. It is designed to be mounted within the wine cellar 
and can be used in combination with Local Interface Controller or 
the Remote Interface Controller and up to two additional Remote 
Sensors to control multiple areas within the wine cellar. 
 
 
 
 
 
 
Mounting the Remote Sensor
 
 
 
 
 
 
 
 
 
 
 Fig.1 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1. Disconnect the communication cable from the back the
remote sensor. Install the communication cable within 
the wall and/or ceiling structure of the wine cellar to the 
desired controller mounting location. 
 
 
 
 
 
 
 
2. Mount the Remote Sensor on a solid surface away from
doors, corners, air outlets, drafts or heat generating 
equipment. Do not mount the Remote Sensor directly on 
an outside wall or wall adjacent to a boiler room. Use a 
piece of foam insulation behind the sensor to insulate it 
from a hot or cold surface. The recommended height is 
4 to 5 feet above the finished floor. 
3. Remove the sensor cover plate by removing the two
allen head screws at the top of the cover using the allen 
head wrench provided in the kit.(Fig.2) Mark the 
mounting points at the desired location within the wine 
cellar. Also mark the location of the communication 
cable connection as this area will require sufficient 
clearance, for instance 1½” hole in the wall for flush 
mounting of the sensor plate. 
Fig.1
Important
A splitter device has been supplied within the Remote 
Sensor kit. The splitter device must be mounted at the 
WG unit.. DO NOT mount the splitter device at the back 
of the Remote Interface Controller or to the back of the 
Remote Sensor as this WILL cause component or system 
damage. 