Other miscellaneous problems, Problems controlling cellar humidity – Vintage Cellars Through-the-Wall Wine Cellar Cooling System Manual User Manual
Page 44
 
44
 
 
 
Humidity too high when unit is not 
running 
Possible Cause
Solution
System needs to run to dehumidify
Lower room temperature setpoint. Seal 
openings around doors (gasket and sweep) 
Humidity too high when unit is running 
and cooling 
Possible Cause
Solution
Too much moisture in cellar
Poor vapor barrier installation 
Humidifier malfunction refer to the humidifier 
instructions 
 
Add dehumidifier to surrounding space 
Other Miscellaneous Problems
System is leaking water
Possible Cause
 
Solution 
Condensate pan plugged
Unit not level
Remove blockage and clean
Level with shims
System is running properly, but the sounds 
of unit is objectionable 
Possible Cause
Solution
Noise is from airflow
Duct airflow from condenser to outdoors
 
 
 
 
 
Problems Controlling Cellar Humidity