Set up / batteries, Assembly instructions (continued), Set up – Welch Allyn PROPLUS 2101KGWA Health-o-Meter Professional Scales - User Manual User Manual

Page 7

Advertising
background image

6

ASSEMBLY INSTRUCTIONS (CONTINUED)

Assembling a 2101KGWA Scale (continued):









Figure 2

12. Carefully tilt the scale back to an upright position on the floor. DO NOT DROP THE SCALE. Adjust the feet, to level

the scale. Be certain that the feet are NOT completely tightened into the base (see Step 11, above).

13. Rotate the display support 90˚ then position the Display Assembly close to the Display Support. Plug the load cell

cable connector into the load cell port on the rear of the Display then insert and secure the cable into the center

channel in the display. See Figure 2, above, for an illustration. Note: Do not attach the power cord at this point.

Wait until Step 19.

14. Slide the display assembly onto the metal display support insuring that the two metal tabs go into the two slots in the

rear of the display. Note: The load cell cable should now be secured in the channel between the display
assembly and the display support.

15. Insert four (4) Phillips pan head M4 screws (E) into the metal display support, and tighten (see Figure 1).

16. Attach the Adapter Holder to the center rail using two (2) #8 x ½ (D) sheet metal screws, and tighten.

17. Connect the power adapter to the power port in the display, then insert and secure the cable into the exposed

portion of the second channel from the left in the back of the display (see Figure 2, above). Hold the cord in place

through the retaining slot on the rear cover and align the large rear cover tabs with the slots on the rear of the

display assembly. Apply light pressure to snap the cover into place and secure it with two (2) Phillips pan head M4

screws (E). Do not plug the scale into a power source until the scale is fully assembled.

18. Rotate the display to align it with the center handrail then attach the front and small rear display support covers,

applying light pressure to snap these covers into place.

19. Secure the power cord to the inside of the center handrail, using the 4 plastic cable clips, arranged to hold the cord

out of the way. The adhesive backing on the clips will peel off then the clips can be fastened to the scale by applying

light pressure.

20. The scale is now assembled. Plug the scale adapter into a power source and / or insert batteries.

SET UP

ProPlus

®

2101KGWA scale is shipped with the Menu Lock function enabled. The Menu Lock function disables certain

buttons on the scale’s keypad, preventing unauthorized users from making changes to your scale settings. The Menu

Lock can be bypassed temporarily to allow you to customize your scale with the functionality you prefer. Please refer to

the ProPlus

®

Display Module User Manual for instructions on how to bypass the Menu Lock.

Preparing the Scale for Use

1. Remove protective plastic films covering the keypad and display.

2. Place batteries in the battery holder (see “Batteries” information in Figure 3, below).

3. Plug the scale’s power adapter into the power source.

4. Be sure all objects are removed from the scale’s platform, and then press the ON/OFF or I/O button to turn the

scale on. The display will show “Health o meter ProPlus” and then “0.0KG”. Note: To adjust the display backlight

and/or contrast, please refer to the ProPlus

®

Display Module User Manual.

Note

: The scale will always default to the settings and units last used .

5. When you disconnect the scale’s power adapter from the power source, the scale will switch to battery power, if

batteries are installed. Note: If the set up procedure failed, refer to the troubleshooting instructions. If the problem

is not corrected, refer to qualified service personnel.