Milano Twin Brewer – Service Manual

The Curtis ThermoPro Brewer is Factory Pre-Set and Ready to Go… Right from the Carton.

Following are the Factory Settings for your Coffee Brewing System:

• Brew Temperature = 200°F

• Water Bypass = On for LARGE & MEDIUM Brew Only

• Brew Volume = Set to Vessel Requirement.

• Sleep Mode = Off

System Requirements:

• Water Source 20 – 90 PSI (Minimum Flow Rate of 1 GPM)

• Electrical: See attached schematic for standard model or visit www.wilburcurtis.com for your model.

SETUP STEPS

The unit should be level (left to right and front to back), located on a solid counter top. Connect a water line from the water filter to the

brewer.

NOTE: A water filtration system must be used to help maintain trouble-free operation. Air must be purged from the cartridge prior to

connection to equipment. In areas with extremely hard water, we highly recommend the use of a Curtis approved water filter. For our

full line of filters, please log on to www.wilburcurtis.com.

1. A 3/8” NPT x 3/8” Flare elbow has been supplied for water line connection. Use tubing sized sufficiently to provide a minimum of 1.0

GPM.

2. To hookup the InterLock grinder, Locate the jack labeled “Class 2 Wiring Only” on brewer and grinder. Connect the two with the cable

plug.

3. Connect the unit to an appropriate electrical power circuit.

4. Turn on the toggle (STANDBY/ON) switch behind the unit. The heating tank will start to fill. When the water level in the tank rises

to the correct volume, the heating elements will energize automatically. With ADS Systems there is no danger of element burnout

caused by an empty tank.

5. The heating tank will require 20 to 30 minutes to reach operating temperature (200°F). You will be notified when READY-TO-BREW

appears on the control panel LCD screen.

6. Prior to brewing, dispense 12 ounces of hot water through the hot water faucet.

7. Brew a cycle of at least 12 ounces, to purge the water lines of any air that may be trapped after filling.

W

ilbur

C

urtis

C

ompany

, i

nC

.

Models Included
u

TPC15T

u

TPC2T

CAUTION: DO NOT

connect this brewer to

hot water. The inlet valve

is not rated for hot water.

CAUTION: Please use

this setup procedure

before attempting to use

this brewer. Failure to follow the

instructions can result in injury or the

voiding of the warranty.

WARNING TO AVOID

SCALDING, Do not

remove brewcone while

brew light is flashing.

IMPORTANT: Equipment

to be installed to comply

with applicable federal,

state, or local plumbing/electrical

codes having jurisdiction.

BREWING INSTRUCTIONS

1. Brewer should be ON (Confirm at rear toggle switch, then press the ON/OFF button). Ready-to-Brew should read on the LCD screen. If

connected to an InterLock grinder, grinder should be on. Grind coffee at this time.

2. Place an empty Milano server under the brewcone.

6. Press Brew button.

Brewing will begin

immediately.

5. Transfer filled

brewcone to brewer.

3. Place a clean filter into

the brewcone.

4. Fill brewcone with

ground coffee.

This equipment is designed for commercial use. Any servicing other than cleaning and routine maintenance should be performed by an

authorized Wilbur Curtis Company Service Technician.

• DO NOT immerse the unit in water or any other liquid

• To reduce the risk of fire or electric shock, DO NOT open service panels. There are no user serviceable parts inside.

• Keep hands and other items away from hot areas of the unit during operation.

• Never clean with scouring powders or harsh chemicals.

Important Safeguards/Symbols

Symbols:

WARNINGS – To help avoid personal injury

Important Notes/Cautions – from the factory

Sanitation Requirements

NSF International requires the following water connection:

1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) is required so that the unit can be moved

for cleaning.

2. This unit must be installed with adequate back-flow protection to comply with applicable federal, state and local codes.

3. Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed and maintained

in accordance with federal, state, and local codes.