Wilbur Curtis GEM3IF User Manual

Service manual – gemini intellifresh brewer

Advertising
background image

1

Important Safeguards/Conventions

This appliance is designed for commercial use. Any servicing other than cleaning and preventive maintenance

should be performed by an authorized Wilbur Curtis service technician.

• DO NOT immerse the unit in water or any other liquid

• To reduce the risk of fire or electric shock, DO NOT open the service panels. There are no user service-

able parts inside.

• Keep hands and other items away from hot surfaces of unit during operation.

• Never clean with scouring powders, bleach or harsh chemicals.

Symbols

WARNINGS – To help avoid personal injury

Important Notes/Cautions – from the factory

Sanitation Requirements

Your IntelliFresh brewer is Factory Pre-Set and Ready to Go… Right from the Box.
Following are the Factory Settings for IntelliFresh brewer:

• Brew Temperature = 200°F

• Water Bypass = On LARGE & MEDIUM brew only

• Brew Volume = Large-Medium-Small

• Energy Save Mode = Off

• Quality Timer = 120 Minutes

• Warmer Auto-Off = 10 Hours

System Requirements:

• Water Source 20 – 90 PSI (Minimum Flow Rate of 1 GPM)

• Electrical: See attached schematic for standard model or visit www.wilburcurtis.com for your model.

SETUP STEPS

The unit should be level (left to right and front to back) and located on a secure counter top. Connect a water

line from the water filter with a minimum flow rate of 1 gallon per minute to the brewer.

NOTE: A water filtration system may be used to maintain trouble-free operation. In areas with extremely hard

water, we suggest that a sedimentary and taste & odor filter (Curtis p/n CSC5AC00, CSC10AC00, & CS-

C15AC00) be installed. This will prolong the life of your brewing system and enhance coffee quality.

1. A 3/8”Flare x 3/8” Male pipe elbow is supplied with the brewer for water line connection. Use tubing sized

sufficiently to provide a minimum of 1.0 GPM.

2. Connect the unit to an appropriate electrical power circuit.
3. Turn on the toggle (STANDBY/ON) switch behind the unit. The heating tank will start to fill. When the water

level in the tank rises to the correct volume, the heating elements will energize automatically. With the

IntelliFresh brewer, there is no danger of element burnout caused by overheating an empty tank.

4. The heating tank typically requires 20 to 30 minutes to reach operating temperature (200°F), indicated

when READY is displayed on the LCD screen.

5. Prior to brewing, dispense 12 ounces of hot water through the hot water faucet.
6. Brew a cycle of at least 12 ounces, to purge the water lines of any air that may be trapped after filling.

W

ilbur

C

urtis

C

ompany

, i

nC

.

Models

GEMTIF

GEMSIF

GEM3IF

Service Manual – Gemini IntelliFresh Brewer

CAUTION: DO NOT

connect this brewer to hot

water. The inlet valve is

not rated for hot water.

CAUTION: Please use

this setup procedure

before attempting to use

this brewer. Failure to follow the

instructions can result in injury or the
voiding of the warranty.

IMPORTANT: Equipment

to be installed to comply

with applicable federal,

state, or local plumbing/electrical

codes having jurisdiction.

FOR THE LATEST SPECIFICATIONS AND INFORMATION GO TO WWW.WILBURCURTIS.COM

ISO 9001:2008

Wilbur Curtis Company

Montebello, CA 90640

Tel: (323) 837-2300

www.wilburcurtis.com

NSF International requires the following water connection:

1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) so that the machine

can be moved for cleaning underneath the unit.

2. This equipment is to be installed with adequate back flow protection to comply with applicable

federal, state and local codes.

3. Water pipe connections and fixtures directly connected to a potable water supply shall be sized,

installed and maintained in accordance with federal, state, and local codes.

Advertising