e. Receiver Section

The receiver section consists of quench expansion
valve, manual liquid line valve, filter-drier, receiver
with sight glass/moisture-liquid indicator, condenser

pressure transducer (CPT), fusible plug, suction
modulation valve, suction solenoid valve, and

discharge pressure regulator valve.

The supply temperature sensor (STS), supply recorder
sensor (SRS) and ambient sensor (AMBS) are located at
the right side of the compressor.

17

1

2

10

5

6

13

14

11

12

9

8

7

15

16

3

4

18

19

1. Discharge Pressure Regulator Valve

2. Suction Modulation Valve (SMV)

3. Schrader Valve

4. Supply Air Thermometer Port -- Optional

5. Suction Solenoid Valve (SSV)

6. Quench Expansion Valve

7. Electro-Coated Modular Receiver

8. Sight Glass

9. Fusible Plug

10. Condenser Pressure Transducer (CPT) --

Located on back side of Receiver)

11. Sight Glass/Moisture Indicator

12. Filter-Drier

13. Manual Liquid Line Valve

14. Ambient Sensor (AMBS)

15. Supply Temperature Sensor (STS)

16. Supply Recorder Sensor (SRS)

17. High Pressure Switch (HPS)

18. Thermistor Sensor (CPDS)

19. Thermistor Sensor (CPSS)

Figure 2-5. Units with Receiver