3-4

T-268-07

3.1.3

General Layout of the Controller Section

The Micro-Link 2i Controller/DataCORDER consists
of a key pad, display module and Controller module.
Connectors are used to attach the wiring of the unit to

the Controller module. The Controller module is
designed to permit ease of installation and removal.
All control functions are accessed by key pad selections

and viewed on the display module which are designed
for optimum user friendliness and convenience.
The key pad (see Figure 3-1) is mounted on the
right-hand side of the control box. The key pad consists
of eleven push-energized membrane switches that act as
the user’s interface with the Controller and the optional
DataCORDER. Refer to Table 3-2.

ENTER

BATTERY

POWER

DEFROST

INTERVAL

CODE

SELECT

PRE

TRIP

ALARM

LIST

ALT.

MODE

RETURN

SUPPLY

_

C

_

F

Figure 3-1. Key Pad

Table 3-2. Key Pad Function

KEY

FUNCTION

Arrow Up

Change set point upward. Change

codes upward. Scan alarm list upward.

Change

user

selectable

features

upward. Pre-trip advance forward.

Pre-trip test interruption. DataCORDER

Function and Alarm Codes are scrolled

upward after the ALT. MODE key is

depressed.

Arrow Down

Change set point downward. Change

codes downward. Scan alarm list

downward. Change user selectable

features downward. Pre-trip repeat

backward. DataCORDER Function and

Alarm Codes are scrolled downward

after the ALT. MODE key is depressed.

Return/Sup

ply

Displays

non-controlling

probe

temperature (momentary display).

_

C/_F

Displays alternate temperature scale

(momentary display).

Alarm List

Displays alarm list and clearing of the

alarm queue (when followed by Enter

key) for the Controller, and also for the

DataCORDER after the ALT. MODE

key is depressed.

Code Select

Access function codes (see arrow up

and arrow down) for the Controller,

and also for the DataCORDER after

the ALT. MODE key is depressed.

Defrost

Interval

Displays selected defrost interval.

Pre–Trip

Displays a pre-trip selection menu.

Discontinues pre-trip in progress.

Battery

Power

If the unit is equipped with the optional

battery pack, initiate the battery

backup mode to allow set point and

function code selection if no mains

power is present.

Enter

Entering

a

set

point

change.

Extending to 30 seconds the time a

chosen

data function

code is

displayed. Entering the value of a user

selectable mode. Clearing the alarm

list and initiating pre-trip. Also used for

various DataCORDER functions after

the ALT. MODE key is depressed.

ALT. Mode

Allows access to DataCORDER

function

codes,

alarm

codes,

DataCORDER

configuration

and

scrollback.

Advertising