4 unit specific configuration operation, 1 unit type → art2000, 1 displaying art2000 parameters – BendixKing KPA 900 System RDR-2000 User Manual

Page 26: 2 changing art2000 parameters in the kpa900

Advertising
background image

BENDIX/KING®

KPA 900

Page 3-6

Revision 2

©Honeywell International Inc. Do not print without express permission of Honeywell.

Dec/2007

3.4 UNIT SPECIFIC CONFIGURATION OPERATION

3.4.1 UNIT TYPE

→ ART 2000

The KPA 900 allows the user to specify optional characteristics and optional features for
the ART 2000 weather radar. Refer to Section 4.1 for a description of the parameter
function. Differences in the feature sets of the ART 2000 and ART 2100 are controlled by
the unit hardware and software. Attempts to configure an ART 2000 to provide an ART
2100 feature through the CM 2000 will not provide the feature and may cause malfunction.

3.4.1.1 DISPLAYING ART 2000 PARAMETERS

The ART 2000 parameter frame is displayed by selecting the ART 2000 from the Unit
Type menu, loading a configuration file for ART 2000, or reading a CM 2000 that is
programmed for ART 2000. Figure 3-3 shows the ART 2000 parameter frames with the
default values.

There are two pages of parameters available, but only one can be viewed at any time. The
page that is not on screen is viewed by moving the vertical scroll control to the upper or
lower position.

Figure 3-3 – KPA 900 Main Form with ART 2000 Unit Type Selected

3.4.1.2 CHANGING ART 2000 PARAMETERS IN THE KPA 900

The options available for each parameter are listed as option buttons grouped in a frame
with the parameter name. To select a different option for the parameter, click on the
desired option. The selected option receives the black dot inside the circle which indicates
a successful selection. A line is added to the activity log to indicate the change and the
new value.