8 tools → view edit art stab – BendixKing KPA 900 System RDR-2000 User Manual

Page 39

Advertising
background image

BENDIX/KING®

KPA 900

Page 3-19

Revision 2

©Honeywell International Inc. Do not print without express permission of Honeywell.

Dec/2007

Figure 3-14 – Factory Test Form, Test in Progress Screen

3.6.8 TOOLS

→ VIEW EDIT ART STAB

CAUTION:

BE CAREFUL WHEN YOU ADJUST THE VALUES, AS YOU WILL ALTER
THE EXISTING CALIBRATION DATA. MAKE SURE TO DO A MODULE
READ OPERATION, AND SAVE THE CONFIGURATION AND
CALIBRATION TO A SEPARATE FILE BEFORE YOU MAKE ANY
ADJUSTMENTS. THIS FILE CAN BE RESTORED IF NECESSARY.

The View/Edit ART Stab tool provides a way to see the results of a stabilization calibration
and to make adjustments if necessary. The CM 2000 must be read through the
Tools

→ Read from CM 2000 menu option, and then through the

Tools

→ View/Edit ART Stab menu option.

NOTE: The preferred method of performing a stabilization calibration is included in the

installation manual for the ART. This is an alternative procedure to slightly modify
an existing calibration that is not working as expected.

Figure 3-15 shows the View/Edit ART Stab Calibration form with the uncalibrated default
values. There are two main frames, one for the analog gyro and one for the digital gyro.
Only the values for the configured gyro source are significant to the ART.

To find if the system is calibrated, compare the existing display with the default values
shown in Figure 3-15. A calibration was completed if any field has been changed.

Advertising
This manual is related to the following products: