Chapter 4 Data Interfaces

Multi-Channel Interfaces

55

Table 4-8. RS-366A Adapters

4.6.2 RS-449/422 Interface

This interface complies with EIA Standard RS-449. Electrical characteristics comply with RS-422
for clock and data signals and RS-423 for control signals. The interface uses the physical
connector type and pinouts specified in RS-449 (refer to Table 4-9). The RS-449/422 interface
uses a 37-pin, female D-Type connector for the physical connection.

Table 4-9. RS-449 Pinouts for Model MC1

Pin

Number

A/B

RS-449 Pin

Name (abbrev)

(full name)

Direction

1

SHLD

shield

-

4/22

SD

send data

to modem

5/23

ST

send timing

from modem

6/24

RD

receive data

from modem

7/25

RS

request to send

to modem

8/26

RT

receive timing

from modem

9/27

CS

clear to send

from modem

10

LL

local loopback

to modem

11/29

DM

data mode

from modem