2 rs-449/422 interface, Rs-449/422 interface – CANOGA PERKINS 2240 Fiber Optic Modem User Manual
Page 55
Chapter 4 Data Interfaces
Multi-Channel Interfaces
55
Table 4-8. RS-366A Adapters
4.6.2 RS-449/422 Interface
This interface complies with EIA Standard RS-449. Electrical characteristics comply with RS-422
for clock and data signals and RS-423 for control signals. The interface uses the physical
connector type and pinouts specified in RS-449 (refer to Table 4-9). The RS-449/422 interface
uses a 37-pin, female D-Type connector for the physical connection.
Table 4-9. RS-449 Pinouts for Model MC1
Pin
Number
A/B
RS-449 Pin
Name (abbrev)
(full name)
Direction
1
SHLD
shield
-
4/22
SD
send data
to modem
5/23
ST
send timing
from modem
6/24
RD
receive data
from modem
7/25
RS
request to send
to modem
8/26
RT
receive timing
from modem
9/27
CS
clear to send
from modem
10
LL
local loopback
to modem
11/29
DM
data mode
from modem