Chapter 4 Data Interfaces

Programmable Buffered Interface/Model P53

67

Figure 4-4 BNC Connectors

4.9 Programmable Buffered Interface/Model P53

The Model P53 Interface Module complies with EIA Standard RS-530 while all clock, data and
control signals follow the RS-422 standard. The basic configuration of the P53 interface is a DCE
device (w/Fem DB-25) and two connector adapters are provided with the interface: the DCE/DTE
adapter which converts the interface to the DTE form (w/Male DB-25) and the "Legacy" adapter
which converts the interface to the original Model P2 interface.

This interface implements a set of circuits (resources) which can be interconnected in various
ways to satisfy a host of differing applications. These resources are:

a 16-bit FIFO (first-in, first-out) buffer

Table 4-16. BNC Supported Signals

Signal

Full Name

Direction

TxD

Transmit Data

To Modem

RxD

Receive Data

From Modem

SCR

Serial Clock Receive

From Modem

SCT

Serial Clock Transmit

From Modem

SCTE

External Clock Transmit

To Modem

Receiver Clock

Received Data

Transmitted Data

Transmitter Clock

External
Transmitter Clock

or