Chapter 4 Data Interfaces

2240 Fiber Optic Modem User Manual

High-Speed RS-422/Mil-Std 188-114C Interfaces

80

SCT should be selected if the modem is set for Internal or Slave Clock mode.

SCTE should be selected if the modem is set for External Clock mode.

NOTE: The SCT output cannot be returned on the SCTE leads to eliminate

propagation delay problems with this interface.

4.10.2 Model TW8

The signaling used on this interface is Mil-Std 188-114C. Four TwinAx connectors (BJ-77, 3-lug)
are used for the physical connection (see Figure 4-16).

A switch is provided to select whether the fourth TwinAx (SCT/SCTE) is to be used as an output
(SCT) or as an input (SCTE). By setting the switch to the SCT position, the port becomes an
output providing the clock to the connected device. When set for SCTE, the port becomes an
input and will accept a clock from the connected device.

T22

RS-422A

5 TwinAx

Figure 4-17

<100 Ohms

100 Ohms ±10%

T88

Mil-Std 188-114C

5 TwinAx

Figure 4-17

<100 Ohms

78 Ohms ±10%

D22

RS-422A

DC-37

Table 4-23

<100 Ohms

100 Ohms ±10%

D88

Mil-Std 188-114C

DC-37

Table 4-23

<100 Ohms

124 Ohms ±10%

Table 4-22. Jumper Strap Options

Jumper ID

Description

Factory Configuration

TW

TW8

T22

T88

D22

D88

W3/W4*

W3 = VCO disabled
W4 = VCO enabled

W4

W4

W4

W4

W4

W4

W5/W6**

W6 = Normal SCT
W5 = Inverted SCT

W6

W6

W6

W6

W6

W6

W5/W6

W7 = Shield connected to chassis ground
W8 = Shield connected to signal ground

W7

W7

W7

W7

W7

W7

W9/W10

W9 = Chassis ground connected to signal ground
W10 = Not connected

W10

W10

W10

W10

W10

W10

E2

TxD RCV termination resistor

N/A

IN

N/A

IN

N/A

IN

E3

SCTE RCV termination resistor center tap to
shield ground

N/A

IN

N/A

IN

N/A

IN

* W3/W4 jumper option may not exist on some older versions. It is only required when performing Local
loopbacks. The W4 position corrects the duty cycle of External Clock above 9 Mbps.
** The W5/W6 jumper option serves the same function as the SCT Normal/Invert Jumper on the main
2240 board. Either one can be used to invert SCT. Refer to section 2.1.6 for details.

Table 4-21. Model Characteristics (Continued)

Model

Electrical Interface

Type

Physical

Interface

Type

Physical

Interface

Figure/

Table

Driver

Impedance

Termination

Impedance

Advertising