18.13.1.3 Command

Mode

Track mode

18.13.1.4 Defaults

Default value is 0 seconds.

18.13.1.5 Examples

In the following example, the delay up command is used to configure delay when object state is
turned from down to up:
Switch(config)#track 1
Switch(config-track)#delay up 30

18.13.1.6 Related

Commands

Show track

18.14 DELAY DOWN

To specify a period of time (in seconds) to delay communicating state changes of a tracked
object, use delay down in track mode. To come back to default value, use the no form of this
command.

18.14.1.1 Command

Syntax

delay down seconds
no delay down

18.14.1.2 Syntax

Description

seconds

Time range is from 1 to 180.

18.14.1.3 Command

Mode

Track mode

18.14.1.4 Defaults

Default value is 0 seconds.

18.14.1.5 Examples

In the following example, the delay down command is used to configure delay when object state
is turned from up to down:
Switch(config)#track 1
Switch(config-track)#delay down 30