Connection with alarm unit & time lapse vtr – Panasonic WJ-SQ508 User Manual

Page 12

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Note:

1

.

The example illustrated above performes sequential

switching of the cameras in the following order:

1

—*■

3 — > 5 — ^ 7 — + 2 — ^ 4 — >

6—+8

with a corresponding

dwell time.

2.

If a "CH" number has been set twice, an arrow mark

points out the lower "CH" to be corrected.

ORDER CH DWELL BYPASS

(S)

1

1

2

PASS

2

3

2

3

5

2.5

*

4

7

3

*

5

2

2

6

4

1.5

7

3^ 3.5

*

8

8

3

*

CONNECTION WITH ALARM UNIT & TIME LAPSE VTR

• Connect the sensor switches and the Time Lapse VTR

with the proper cables. The sensor should have an
open-collector output or non-voltage contact,

(Time Lapse VTR)

Alarm switch 1 to 8

When the alarm time of the Time Lapse VTR is set
shorter than the Sequential Switcher WJ-SQ508, the
alarm mode of the Time Lapse VTR will be finished
faster than the Sequential Switcher. At this time, the

Time Lapse VTR will cease the alarm mode of the
Sequential Switcher.

When the alarm signal is supplied to the WJ-SQ5O0,
the letters of "AL" blinks on the video monitor through
the Alarm/Sequence Video Output Connector (22) or
the Spot/Sequence Video Output Connector (23).
When the alarm unit has to be connected with the Alarm

Output Connector (39), refer to the diagram below. The

capacity of the Alarm Output Connector (39) is 16V DC

maximum

1

00mA or less. Use a Relay Box if necessary.

ALARM OUT

-

1 1

-

Advertising