4. Parallel connection with VTR

SPOT/SEQ OUT

□ □

ALARM/SEQ OUT

(A)

VTR

o.ood6oo6$oir №

ooodooDbiSo

, ®

0.000000000

6006600

b5o

iVrrrri I C

SPOT/SEQ OUT

(C)

ALARM/SEQ OUT

6

oodbood™-

DOOOOOObS^

¥ _

(2) ALARM/SEQ OUT —> WJ-SQ508 in spot mode

and the other WJ-SQ508 are switched by to the

timing pulse from the VTR.

(g) Single alarm mode;

(

1

) SPOT/SEQ OUT - When the unit (B) is alarmed,

i.

the unit (B) and (C) starts sequence in every
one second.

ii.

the unit (A) continues a previous operation.

(2)

ALARM/SEQ OUT —» WJ-SQ508 in alarm mode

fixed to the alarmed picture. Other WJ-SQ508

continue the sequence mode synchronized with
timing pulse from the VTR.

(h) Multiple alarm mode:

(

1

) SPOT/SEQ OUT - When the unit (B) is alarmed,

i,

the unit (B) and (C) starts sequence in every
one second.

ii,

the unit (A) continues a previous operation.

(

2

)

ALARM/SEQ

out

—^ Alarmed channels of

alarmed WJ-SQ508 start sequencing out once
every

second.

Other

WJ-SQ508

continuethe

sequence mode synchronized with timing pulse
from the VTR.

(i)

Quick Scan alarm mode;

(

1

) SPOT/SEQ OUT - When the unit (B) is alarmed,

i,

the unit (B) and (C) starts sequence in every
one second.

ii.

the unit (A) continues a previous operation.

(2) ALARM/SEQ OUT starts sequencing out all

pictures in the alarmed WJ-SQ508 in QS-TIME.

Other WJ-SQ508 continued the sequence mode

synchronized with timing pulse from the VTR.

Note:

The Time Lapse VTR can be used with each

Sequential Switcher.

(a) Sequence time; Set by timing pulse from VTR for all

WJ-SQ508.

(b) Controls:

(1)

Master/Slave Switch (27) set to Master position

for all WJ-SQ508.

(

2

)

Station Number Switch (29) & Unit Number Switch

(30) are not specified.

(3) Dwell Time Control (5) of all WJ-SQ508 set to EXT

position.

(c) The Sequence mode of the system stops when the

power of the VTR is turned off due to no timing pulse.

(d) Normal sequence mode:

(1)

SPOT/SEQ OUT All WJ-SQ508 are switched

by the timing pulse from VTR

(2)

ALARM/SEQ OUT All WJ-SQ508 are switched

by the timing pulse from VTR.

(e) Program sequence mode:

(

1

) SPOT/SEQ OUT All WJ-SQ508 are switched

by the timing pulse from VTR with self programmed
menu.

(f)

Spot mode:

(

1

) SPOT/SEQ OUT -> WJ-SQ508 in spot mode

shows the spot picture. Other WJ-SQ508 are
synchronized to the timing pulse from the VTR.

- 1 9 -