Oberkorn User Manual

Analogue Solutions | EXPLANATION OF EACH CONTROL

13

Use a CV keyboard to transpose the pitch of the sequencer (note transpose inputs are not
calibrate beyond 1% so scaling may be an issue).

GATE CHANNELS

There are two Gate channels, X and Y.

Each channel is completely independent form the others, though they will be clocked
together and be of the same sequence length.

Gate Switch (rotary switch)

The 16 gate switches each have four positions.

Position 1: X

In this position there will be a gate signal from the X GATE OUT socket when this step is
played.

Position 2: Y

In this position there will be a gate signal from the Y GATE OUT socket when this step is
played.

Position 3: X+Y

In this position there will be gate signals from both GATE OUT sockets when this step is
played.

Position 4: OFF

In this position there will be no gate signalS from either of the GATE OUT sockets when this
step is played.