CHANGING PATTERN LENGTH

Normally the sequencer runs from 1-16 – creating a 16 step sequence (4 bars).

It’s possible to create shorter sequencer – and even change the sequence length in real time
by patching Gate X or Y into Reset In.

Then the sequencer will reset back to step one early as soon as it receives a gate signal.

So, for example, to create an eight step sequencer set all gate switches off but have gate
switch 9 on. So to set the length, add one to the length and that’s the switch to set. The
position of subsequent switches doesn’t matter since they won’t be used.

The pattern length can then be changed in real time by changing switch positions.

Pattern length can of course be also changed/sequencer reset using an external voltage too.