6 - 4

Cub Cadet 3000

The spool/sleeve assembly may be removed from the
control valve housing in either the vertical or horizon-
tal position.

VERTICAL POSITION
Carefully reposition the control valve assembly in the
vertical position with the meter end of the control
valve housing pointing upward. Remove the
spool/sleeve assembly from the control valve housing.

IMPORTANT: Do not bind the spool/sleeve assembly
in the control housing.

Rotate the spool/sleeve assembly slightly and slowly
when removing from the control housing.

HORIZONTAL POSITION
Rotate the spool/sleeve assembly until the cross pin
is horizontal with the porting face flange. Position the
control valve assembly with the porting face on a
clean flat surface.

Remove the spool/sleeve assembly from the metering
section end of the control housing keeping the cross
pin in the horizontal position.

IMPORTANT: Do not bind the spool/sleeve assembly
in the control housing.

Rotate the spool/sleeve assembly slightly back and
forth when removing from the control housing.

Figure 16.

Figure 15.

Figure 14.

Push or pull the spool forward to remove it from the
sleeve.

NOTE: Caution must be used not to dislodge the
spring retaining ring during removal of the spool from
the sleeve.

Using a small screwdriver or similar type tool, remove
the cross pin from the spool/sleeve assembly.