Cub Cadet 3000 Series User Manual

Page 56

Advertising
background image

8 - 2

Cub Cadet 3000

9. Finger loosen the pump adapter nut until it is

flush with the end of the hydro input shaft.

10. Place a 13/16 socket against the nut with the

opened end of the socket facing away from the
nut. See figure 6.

11. Place the new pump adapter, cupped side in,

over the opened end of the 13/16 socket. See
figure 5.

12. Finger tighten two of the drive shaft hex screws

across from one another.

13. Using a 3/8 socket, tighten the hex screws

equally a quarter of a turn at a time until the old
hub breaks free. See figure 5.

FIGURE 5.

13/16

Socket

Drive Shaft

Hex Screw

Original Pump

Adapter

New Pump

Adapter

14. Remove the hex screws and new hub. See

figure 5.

15. Remove the hex nut, bell-washer, old pump

adapter, and key from the input shaft.

FIGURE 6.

13/16

Socket

Bell-

Washer

Hex Nut

Drive Shaft

Hex Screws

Original

Pump

Adapter

New Pump

Adapter

INSTALLATION OF THE NEW PUMP ADAPTER

1. Clean the hydrostatic input shaft of any debris.

See figure 7.

2. Apply a light coat of loctite 803 to the taper of the

input shaft. See figure 7.

3. Place the new fan over the cone of the new pump

adapter.

4. Push the new pump adapter and fan onto the

hydro input shaft.

NOTE: The fan will be on the inside of the pump
adapter.

FIGURE 7.

Loctite

Input
Shaft

Fan

5. Install the new bell washer and locknut.

NOTE: Hold the new pump adapter in place with
a drift punch and torque the lock nut to 20 ft. lbs.
See figure 8.

FIGURE 8.

Torque

Wrench

Drift

Punch

Advertising