FLASH CODE
(No.of flashes)

Battery needs recharging

Battery voltage too low

Battery voltage too high

Current limit time out

Brake fault

Out of neutral when power
switched on at key switch

Speed pot error
(wig wag)

Motor volts error

Other internal error

STATUS FAULT CODES

The original manufacturer's settings for this Scooter are:

SPEED CONTROLLER SETTINGS

Warning: Performance adjustments should not be

made which could put the operator in a serious

situation of control or braking. Performance

adjustments should only be made by a person

fully trained and conversant with the

programming process and it's capabilities.

Warning: Incorrect settings could cause injury to

the Scooter operator and/or to bystanders, or

damage to the vehicle and/or surrounding

property.

The forward-reverse speed Controller (Fig 37

page 30) is a state-of-the-art microprocessor

designed to give smooth and safe operation. For

maximum performance, protection and

convenience the Controller is housed in a solid

die cast aluminium case situated under the rear

body cover.

The speed Controller, 'Dynamic' model

DS72KO1(Rhino 70amp) is programmed by

to obtain the maximum performance

and safety for your Scooter.

If in doubt consult your Scooter

Manufacture

SPEED CONTROLLER SETTINGS

Warning:

1 Flash

2 Flashes

3 Flashes

4 Flashes

5 Flashes

6 Flashes

7 Flashes

8 Flashes

9 Flashes

The battery voltage has dropped below 23.3 volts in neutral.
Recharge the batteries soon.

The battery voltage at Controller has dropped to 16.5 volts.
Check the battery condition and the connections.

The battery voltage at the controller is greater the 32 volts.
Check the battery condition and the connections.
Suspect a charger malfunction.

The Controller has detected a shorted or overworked motor.
Check the loom for shorts or check out the motor.
Contact your Service Agent.

Check the Freewheel Lever is fully engaged. Check the Park
Brake and wiring for open or short circuits. Contact your
Service Agent.

Return the speed lever to neutral. Re-adjust the speed lever
neutral if necessary. Consult your Service Agent.

Check speed pot wiring for open or short circuits. Speed pot
may not be correctly set up. Contact your Service Agent.

Motor or wiring is faulty. Contact your Service Agent.

Contact your Service Agent.

Driving still possible

Drive inhibited

Drive inhibited

Drive inhibited

Drive inhibited

Drive inhibited. Drive possible if
neutral selected within 10 secs.

Drive inhibited

Drive inhibited

Drive inhibited

FAULT DISPLAYED
BY PROGRAMMER

SCOOTER
CONDITION

COMMENT

168-3 168-3S

168-4 168-4S

510DX2 510DXs2

1

6

10

4

4

10

60

15

70

6

1

6

10

4

4

10

60

15

70

6

1

6

10

5

4

10

60

15

70

6

1

6

10

4

4

10

60

15

70

6

1

8

8

4

4

10

60

15

70

6

1

8

10

5

4

10

60

15

70

6

OFF

OFF

OFF

OFF

ON

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

ON

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

ON

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

ON

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

ON

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

ON

ON

ON

OFF

ON

SET-UP MENU DESCRIPTIONSETTINGS

Acceleration

Deceleration

Forward Speed

Reverse Speed

Reduce Speed

Buzzer Volume

Motor Resistance

Sleep Time

Maximum Current

Park Brake Delay

OPTION MENU DESCRIPTIONSETTINGS

Single-Ended Pot

Standard Speed Pot

Motor Reverse

Pot Reverse

Brake Checking

Load Compensation

Enable Sleep

Check for Slope

Current Limit Tim

168-4S2b

1

6

10

4

4

10

60

15

110

6

OFF

OFF

OFF

OFF

ON

ON

ON

OFF

ON