2 imbalance switch, Safety information and use – FRITSCH PULVERISETTE 5/4 classic line User Manual
Page 15
1.
Insert the included triangular key (A) into the bore hole on the
bottom side of the PULVERISETTE 5 classic line and turn it to the
right.
2.
Unlock the latch (2) by pressing the hood handle (1).
3.
The hood (3) can now be opened.
4.
The mill can only be switched on again if the hood (3) is closed and
the safety lock (7) has been enabled again by turning the trian-
gular key to the right.
2.6.2 Imbalance switch
The device switches off if there is excessive imbalance. (See
Chapter 6.6 ‘Mass balance’ on page 37)
CAUTION!
The imbalance switch can be disabled at your own risk. The
Fritsch company will give no guarantee for damage
resulting from disabling of the imbalance switch.
NOTICE!
Change these settings only after all work as described in
Chapter 4 ‘Installation’ on page 21 has been carried out!
In the default setting of the imbalance switch, it is acti‐
vated!
Activation / deactivation of the imbalance switch in setup mode:
1.
Press and hold the STOP button on the front of the control panel.
Safety information and use
- 15 -