1.

Insert the included triangular key (A) into the bore hole on the

bottom side of the PULVERISETTE 5 classic line and turn it to the

right.

2.

Unlock the latch (2) by pressing the hood handle (1).

3.

The hood (3) can now be opened.

4.

The mill can only be switched on again if the hood (3) is closed and

the safety lock (7) has been enabled again by turning the trian-

gular key to the right.

2.6.2 Imbalance switch

The device switches off if there is excessive imbalance. (See

Ä

Chapter 6.6 ‘Mass balance’ on page 37)

CAUTION!
The imbalance switch can be disabled at your own risk. The

Fritsch company will give no guarantee for damage

resulting from disabling of the imbalance switch.

NOTICE!
Change these settings only after all work as described in

Ä

Chapter 4 ‘Installation’ on page 21 has been carried out!

In the default setting of the imbalance switch, it is acti‐

vated!

Activation / deactivation of the imbalance switch in setup mode:
1.

Press and hold the STOP button on the front of the control panel.