3.2.4 CONFIGURATION: MULTI-STRIKE PRINT.


NOTE: Multi-strike automatically disables bi-directional printing.


1. Begin with the ENTER light OFF.
2. Turn the thumbwheel switch to position 1.
3. Press the ENTER switch. The ENTER light begins flashing.
4. Turn the thumbwheel switch to position 4.
5. Press the ENTER switch. The ENTER light turns on.
6. Turn the thumbwheel switch to position:
0 for SINGLE STRIKE.
1 for DOUBLE STRIKE.
2 for TRIPLE STRIKE.
3 for 4 X STRIKE.
4 for 5 X STRIKE.
5 for 6 X STRIKE.
6 for 7 X STRIKE.
7 for 8 X STRIKE.
8 for 9 X STRIKE.
9 for 10 X STRIKE.

7. Press the ENTER switch. The ENTER light turns off.


SET MULTI-STRIKE COUNT

FLASH ON OFF (Enter Light)
Single Strike 1 4 0 (Thumbwheel Switch)
Double Strike 1 4 1 (Thumbwheel Switch)
Triple Strike 1 4 2 (Thumbwheel Switch)

3.2.5 CONFIGURATION: BI-DIRECTIONAL PRINT

.

1. Begin with the ENTER light OFF.
2. Turn the thumbwheel switch to position 1.
3. Press the ENTER switch. The ENTER light begins flashing.
4. Turn the thumbwheel switch to position 5.
5. Press the ENTER switch. The ENTER light turns on.
6. Turn the thumbwheel switch to position:
0 for BI-DIRECTIONAL PRINT --- OFF
1 for BI-DIRECTIONAL PRINT --- ON
7. Press the ENTER switch. The ENTER light turns off.


SET BI-DIRECTIONAL PRINT

FLASH ON OFF (Enter Light)
Bi-Direction OFF 1 5 0 (Thumbwheel Switch)
Bi-Direction ON 1 5 1 (Thumbwheel Switch)



REMEMBER: Return the thumbwheel switch to the correct mode