3.3 CONFIGURATION OF BATTERY-BACKUP OPTIONS


The Battery-Backup options rely on the battery for proper

operation. Configure BATTERY ENABLE = ON if any of the
following options are used:

TIME and/or DATE
TICKET NUMBER
BATTERY BACKED UP TOTALS (Special Applications)

If BATTERY ENABLE = ON the IDS152 will test memory for a
battery failure on power up.

3.3.1 BATTERY ENABLE.
3.3.2 SET TIME.
3.3.3 SET DATE.
3.3.4 SET TIME AND DATE PRINT FORMAT.
3.3.5 TICKET NUMBER.

3.3.1 CONFIGURATION: BATTERY ENABLE.

1. Begin with the ENTER light OFF.

2. Turn the thumbwheel switch to position 2.
3. Press the ENTER switch. The ENTER light begins flashing.
4. Turn the thumbwheel switch to position 5.
5. Press the ENTER switch. The ENTER light turns on.
6. Turn the thumbwheel switch to position:
0 for BATTERY ENABLE --- OFF
1 for BATTERY ENABLE --- ON
7. Press the ENTER switch. The ENTER light turns off.




SET BATTERY BACKUP

FLASH ON OFF (Enter Light)
Battery Enable OFF 2 5 0 (Thumbwheel Switch)
Battery Enable ON 2 5 1 (Thumbwheel Switch)













REMEMBER: Return the thumbwheel switch to the correct mode
postition after configuration.